{"created":"2023-05-15T14:51:16.281334+00:00","id":70090,"links":{},"metadata":{"_buckets":{"deposit":"0351a298-e10e-4d45-9c20-71c19a985d7c"},"_deposit":{"created_by":1,"id":"70090","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"70090"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00070090","sets":["10:28"]},"author_link":["688298","688297","688292","688300","688304","688295","688290","688299","688305","688291","688296","688301","688289","688294","688302","688293","688303"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2010-03-17","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"ヘマトキシリン・エオジン(HE染色)は病理標本診断する際の基本的な染色法である。しかしHE染色だけでは確定診断ができない場合があり、必要に応じて特殊染色を施して確定診断の補助としている。例えば、PAS染色・グラム染色・グロコット染色・ワルチン・スタリー染色等がありその際に薄切切片の厚さが重要になる。しかし、実際の薄切作業では、ミクロームのベアリング精度、室内の温度・湿度により、理想の組織厚に統一することは、非常に難しい。今回は各種ミクロトームを用いて、組織厚を比較しミクロトームの精度を検証したので報告する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第5回技術と安全の報告会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"入谷, 理一郎"}],"nameIdentifiers":[{"nameIdentifier":"688289","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小久保, 年章"}],"nameIdentifiers":[{"nameIdentifier":"688290","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石田, 有香"}],"nameIdentifiers":[{"nameIdentifier":"688291","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"舘野, 香里"}],"nameIdentifiers":[{"nameIdentifier":"688292","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"浅野, まき"}],"nameIdentifiers":[{"nameIdentifier":"688293","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白石, 美代子"}],"nameIdentifiers":[{"nameIdentifier":"688294","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中台, 妙子"}],"nameIdentifiers":[{"nameIdentifier":"688295","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"川原, 隼"}],"nameIdentifiers":[{"nameIdentifier":"688296","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西川, 哲"}],"nameIdentifiers":[{"nameIdentifier":"688297","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"入谷 理一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"688298","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小久保 年章","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"688299","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石田 有香","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"688300","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"舘野 香里","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"688301","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"浅野 まき","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"688302","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白石 美代子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"688303","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中台 妙子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"688304","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西川 哲","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"688305","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"病理標本組織作製するために適切な薄切切片について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"病理標本組織作製するために適切な薄切切片について"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-05-07"},"publish_date":"2010-05-07","publish_status":"0","recid":"70090","relation_version_is_last":true,"title":["病理標本組織作製するために適切な薄切切片について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:06:56.572058+00:00"}