{"created":"2023-05-15T14:51:09.423786+00:00","id":69932,"links":{},"metadata":{"_buckets":{"deposit":"18f9945d-dba2-408c-b519-69f0a4222ad0"},"_deposit":{"created_by":1,"id":"69932","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"69932"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00069932","sets":["10:28"]},"author_link":["686645","686646","686647"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2009-11-05","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"There is a great interest to find nuclear accidents as soon as possible and/or to carry out daily monitoring and control for nuclear facilities from a distance. In order to satisfy these requirements, a direction finding gamma-ray detector has been developed as a monitor of gamma-ray leakage from such facilities. The detector comprises three scintillators made of the same material of sodium iodine with thallium NaI(Tl) . Computer simulations and laboratory experiments show the possibility of direction finding of gamma rays with reasonable accuracy.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第35回IEEE主催産業エレクトロニクスに関する国際会議","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Shirakawa, Yoshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"686645","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"686646","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白川 芳幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"686647","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Remote Sensing of Nuclear Accidents Using a Direction Finding Detector","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Remote Sensing of Nuclear Accidents Using a Direction Finding Detector"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-11-09"},"publish_date":"2009-11-09","publish_status":"0","recid":"69932","relation_version_is_last":true,"title":["Remote Sensing of Nuclear Accidents Using a Direction Finding Detector"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:08:46.163457+00:00"}