{"created":"2023-05-15T14:51:02.035922+00:00","id":69763,"links":{},"metadata":{"_buckets":{"deposit":"510b4b27-f7d5-45b0-884d-0567c04837cb"},"_deposit":{"created_by":1,"id":"69763","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"69763"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00069763","sets":["10:28"]},"author_link":["684936","684937","684931","684935","684939","684928","684938","684934","684930","684932","684929","684933"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2009-05-30","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"脳賦活に対する局所脳血流調節機構に関するげっ歯類を用いたこれまでの研究は、麻酔下の実験が主であり、脳賦活時の脳血管反応と運動動態を同時評価することが不可能であった。本研究では覚醒マウスの脳血管反応及び行動様式を同時かつ繰り返し長期間計測可能な実験系について報告する。実験にはC57BLマウス(5w〜7w)を用いた。マウス頭蓋に自家製チャンバーを装着し、計測装置に固定した。自由回転が可能な発泡スチロール上にマウスを乗せ、ボールの回転量から運動量を評価した。頬ひげ刺激に対する脳血管反応を一次体性感覚野においてレーザドップラ法により連続計測した。同一個体において頬ひげ刺激に対する脳血流変化及び運動量を7日間繰り返し計測した。\n7日間の計測において脳血流変化に有意な変動が見られなかったが、運動量においては計測日によるばらつきが認められた。運動量と体性感覚野の活動には相関が認められなかった。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第3回Motor Control研究会 ","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田桑, 弘之"}],"nameIdentifiers":[{"nameIdentifier":"684928","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"正本, 和人"}],"nameIdentifiers":[{"nameIdentifier":"684929","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ヨーナス, オーティオ"}],"nameIdentifiers":[{"nameIdentifier":"684930","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松浦, 哲也"}],"nameIdentifiers":[{"nameIdentifier":"684931","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠, 隆行"}],"nameIdentifiers":[{"nameIdentifier":"684932","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菅野, 巖"}],"nameIdentifiers":[{"nameIdentifier":"684933","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田桑 弘之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"684934","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"正本 和人","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"684935","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ヨーナス オーティオ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"684936","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松浦 哲也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"684937","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠 隆行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"684938","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菅野 巖","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"684939","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"頬ひげ刺激に対する覚醒マウスの脳血管反応","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"頬ひげ刺激に対する覚醒マウスの脳血管反応"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-06-05"},"publish_date":"2009-06-05","publish_status":"0","recid":"69763","relation_version_is_last":true,"title":["頬ひげ刺激に対する覚醒マウスの脳血管反応"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:10:42.320789+00:00"}