{"created":"2023-05-15T14:50:45.227309+00:00","id":69385,"links":{},"metadata":{"_buckets":{"deposit":"ca0abdb1-aa68-4288-8610-7b571ab49c5c"},"_deposit":{"created_by":1,"id":"69385","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"69385"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00069385","sets":["10:28"]},"author_link":["680979","680980","680978","680976","680977","680975"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-06-27","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"密封シート線源を使ったホールボディカウンタの校正用ファントムは汚染の心配もなく、体内分布を再現できる等の利点を持ち、現在用いられているファントムの様々な欠点の克服が期待される。今回、インクジェットプリンターを使って密封シート線源を作成し、作成に伴う安全性と放射能面密度の調整について検討した。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本保健物理学会第42回研究発表会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"宮本, 真衣"}],"nameIdentifiers":[{"nameIdentifier":"680975","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石榑, 信人"}],"nameIdentifiers":[{"nameIdentifier":"680976","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"緒方, 良至"}],"nameIdentifiers":[{"nameIdentifier":"680977","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"成田, 憲彦"}],"nameIdentifiers":[{"nameIdentifier":"680978","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仲野, 高志"}],"nameIdentifiers":[{"nameIdentifier":"680979","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仲野 高志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"680980","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"ホールボディカウンタ校正に用いる密封シート線源の作成","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ホールボディカウンタ校正に用いる密封シート線源の作成"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-06-30"},"publish_date":"2008-06-30","publish_status":"0","recid":"69385","relation_version_is_last":true,"title":["ホールボディカウンタ校正に用いる密封シート線源の作成"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:15:09.350224+00:00"}