{"created":"2023-05-15T14:50:42.102083+00:00","id":69334,"links":{},"metadata":{"_buckets":{"deposit":"0fc30830-b337-489c-87b7-dedb99251bdf"},"_deposit":{"created_by":1,"id":"69334","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"69334"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00069334","sets":["10:28"]},"author_link":["680415","680417","680416"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-05-09","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A target tracking technique using relative displacements of gravity points of cross sectional images of blood vessels was proposed to guide the ultrasound focus in the liver which moves with respiration. Experiments with healthy volunteer livers demonstrated that the average error of the target position estimation was within 3mm. The error was less than 4mm even with a position prediction process for considering time delay between the time points of position estimation and transducer setup. These results suggested that the proposed technique was sufficient for guiding the focus and hence the imaging slab position and orientation for the \"self-reference\" thermometry.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"ISMRM 16th Scientific Meeting & Exhibition","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kokuryo, Daisuke"}],"nameIdentifiers":[{"nameIdentifier":"680415","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"680416","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"國領 大介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"680417","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Hot Spot Tracking for Focused Ultrasound Surgery of Liver using Filtered Venograpy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Hot Spot Tracking for Focused Ultrasound Surgery of Liver using Filtered Venograpy"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-05-12"},"publish_date":"2008-05-12","publish_status":"0","recid":"69334","relation_version_is_last":true,"title":["Hot Spot Tracking for Focused Ultrasound Surgery of Liver using Filtered Venograpy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:15:43.757806+00:00"}