{"created":"2023-05-15T14:50:40.496080+00:00","id":69297,"links":{},"metadata":{"_buckets":{"deposit":"1a7649c2-38fe-47b3-9f44-727313310535"},"_deposit":{"created_by":1,"id":"69297","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"69297"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00069297","sets":["10:28"]},"author_link":["680052","680051","680048","680053","680055","680049","680054","680050","680046","680047"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-03-07","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"PIXE分析法は、加速されたイオンビームを試料に照射し、放出される特性X線のエネルギーを測定して元素分析を行う方法である。この方法は、少ない試料でも繰り返し測定できる、定量可能な多元素同時分析法ということから、近年、加速器を持つ様々な研究・教育機関でエアロゾルなど、環境試料の解析を目的として開発、利用されるようになってきた。これまで生体内や環境資料中の微量元素分析が多く、そのほとんどの分析ターゲットがCd以下であった。しかしながら、PIXE分析システムが共用施設として指定され、共同研究が増加したしたことから分析範囲が広がり、Pb 、Ag等の重元素分析の必要性が出てきた。 このためにSi(Li)検出器と純ゲルマ検出器の二つの検出器を設置し、軽〜重元素同時分析法の評価を行った。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"平成19年度 実験・実習技術研究会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"680046","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯, 浩之"}],"nameIdentifiers":[{"nameIdentifier":"680047","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西, 輝昭"}],"nameIdentifiers":[{"nameIdentifier":"680048","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野, 毅"}],"nameIdentifiers":[{"nameIdentifier":"680049","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"680050","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"680051","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯 浩之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"680052","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西 輝昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"680053","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野 毅","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"680054","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"680055","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Si(Li)検出器と純ゲルマ検出器の二つの検出器を用いた軽〜重元素同時分析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Si(Li)検出器と純ゲルマ検出器の二つの検出器を用いた軽〜重元素同時分析"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-03-11"},"publish_date":"2008-03-11","publish_status":"0","recid":"69297","relation_version_is_last":true,"title":["Si(Li)検出器と純ゲルマ検出器の二つの検出器を用いた軽〜重元素同時分析"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:16:09.447613+00:00"}