{"created":"2023-05-15T14:50:19.313808+00:00","id":68817,"links":{},"metadata":{"_buckets":{"deposit":"0d5dd4cd-b337-4eda-a7de-f534b2d863a1"},"_deposit":{"created_by":1,"id":"68817","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"68817"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00068817","sets":["10:28"]},"author_link":["675411","675412","675413","675414","675415"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2006-12-01","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【緒言】Al2O3:Cは、常温でほとんどフェーディングしない安定な光刺激ルミネッセンス(OSL: Optically Stimulated Luminescence)を示すことから、個人被ばく線量測定用の素子(商品名:ルクセルバッジ、販売元:長瀬ランダウア株式会社)として広く用いられている。同素子のOSLは、結晶の陰イオン格子欠陥(Fセンター)に捕捉され準安定状態になった電子が、強い光刺激を受けることでFセンターから飛び出し、正孔と再結合した結果生じる発光とされるが、Al2O3:CについてFセンターのESRを調べた事例はこれまで見当たらない。そこで我々は、Al2O3:CのESR特性ならびにOSLとESRとの相関性を明らかにすることを目的として、γ線及びX線を用いた照射実験を行った。\n【実験】50mgのAl2O3:C(米国ランダウア社製)に、γ線(60Co, 0.13Gy min-1)およびX線(実効エネルギー:約82keV, 管電圧:200kV)を、それぞれ0.01Gy〜200Gy、0.01Gy〜480Gy(for water)までの範囲の線量で照射し、照射直後から約1年間、XバンドESR装置(日本電子?製; JES-TE100)を用いてESR信号を測定した。\n【結果】試料にγ線を照射するとg=2.0071にピークが得られ、このピークのESR強度(ラジカル量)は、照射量の増大に伴い大きくなった。この傾向はX線照射においても同様であった。また、〜20GyまでESR強度は大きくならないが、それ以上の照射線量域において線量にほぼ比例して直線的にESR強度が増大することが確認された。得られた直線の傾きは、γ線とX線で類似しており、両者の照射線量依存性は似た傾向を示した。また、X線で照射した試料を室温に放置しピークの安定性を1年間に渡って調べた結果、いずれの試料においても高いラジカル安定性が得られ、この傾向もγ線の場合と同様であった。これらの結果から、一般にOSLの効率が低下する高線量域(>20Gy)において、ESRによる線量測定が可能と考えられる。 ","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本放射線安全管理学会第5回学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"保田, 浩志"}],"nameIdentifiers":[{"nameIdentifier":"675411","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高見, 実智己"}],"nameIdentifiers":[{"nameIdentifier":"675412","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小林, 育夫"}],"nameIdentifiers":[{"nameIdentifier":"675413","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"保田 浩志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"675414","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高見 実智己","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"675415","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"酸化アルミニウムのESRによる線量測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"酸化アルミニウムのESRによる線量測定"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-12-04"},"publish_date":"2006-12-04","publish_status":"0","recid":"68817","relation_version_is_last":true,"title":["酸化アルミニウムのESRによる線量測定"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:21:46.074976+00:00"}