{"created":"2023-05-15T14:50:16.577839+00:00","id":68755,"links":{},"metadata":{"_buckets":{"deposit":"deaaadb4-1ed8-40d0-b723-316cd5da65d8"},"_deposit":{"created_by":1,"id":"68755","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"68755"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00068755","sets":["10:28"]},"author_link":["674746","674747"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2006-11-04","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Energy resolution of a position sensitive scintillation beta camera was studied from the viewpoints of statistical and non-statistical components. The statistical component is caused by fluctuation of the number of photo-electrons collected at the anode of a photo-detector and the non-statistical component comes from intrinsic property of the scintillator. The measurement of these components were carried out on the beta camera composed of 6 x 6 x 1 cm3 plastic scintillator plate (PL) and four photomultiplier tubes (PMTs) covered each side face of the PL. We extracted the non-statistical component by comparing the results obtained with conversion electron irradiations and photon from LED. Tests for a small PL with 4 PMTs and a large PL with 32 PMTs gave the intrinsic component of around 10 % (in FWHM) for 207Bi 0.976 MeV conversion electrons. The present method is useful for investigating statistical and non-statistical components to the resolution, and thus to improve and monitor them.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"2006 IEEE Nuclear Science Symposium","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakamura, Hidehito"}],"nameIdentifiers":[{"nameIdentifier":"674746","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村 秀仁","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"674747","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Study of statistical and non-statistical components of energy resolution for position-sensitive beta camera","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Study of statistical and non-statistical components of energy resolution for position-sensitive beta camera"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-11-08"},"publish_date":"2006-11-08","publish_status":"0","recid":"68755","relation_version_is_last":true,"title":["Study of statistical and non-statistical components of energy resolution for position-sensitive beta camera"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:22:29.901208+00:00"}