{"created":"2023-05-15T14:49:59.016264+00:00","id":68393,"links":{},"metadata":{"_buckets":{"deposit":"4288a16b-012b-4585-8beb-deaf322ad069"},"_deposit":{"created_by":1,"id":"68393","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"68393"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00068393","sets":["10:28"]},"author_link":["671392","671393","671395","671394","671391"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2005-11-25","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"OSLを利用した個人被ばく線量測定用の素子に用いられているAl2O3:CについてESR測定を行い、OSL特性とESR特性の相関性を調査した。 Al2O3:C試料にγ線およびX線を照射してESR特性を調べた結果、ESRには母結晶固有のものと思われるホールトラップが寄与している可能性が示唆された。照射線量に対する応答性は約10Gy以上と高かったが、このラジカルはOSL同様に室温で高い安定性を示した。今回の結果より、ESR特性にはOSLで観測されるFセンターは寄与せず、両者の相関性は低いことが分かった。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本放射線安全管理学会第4回学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"保田, 浩志"}],"nameIdentifiers":[{"nameIdentifier":"671391","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高見, 実智己"}],"nameIdentifiers":[{"nameIdentifier":"671392","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小林, 育夫"}],"nameIdentifiers":[{"nameIdentifier":"671393","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"保田 浩志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"671394","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高見 実智己","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"671395","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"アルミナOSL線量計のESR信号について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"アルミナOSL線量計のESR信号について"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-06-12"},"publish_date":"2006-06-12","publish_status":"0","recid":"68393","relation_version_is_last":true,"title":["アルミナOSL線量計のESR信号について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:26:38.906568+00:00"}