{"created":"2023-05-15T14:49:58.354100+00:00","id":68383,"links":{},"metadata":{"_buckets":{"deposit":"e023c983-8927-4a8f-b9f6-cc000e7d45ed"},"_deposit":{"created_by":1,"id":"68383","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"68383"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00068383","sets":["10:28"]},"author_link":["671327","671328","671323","671324","671326","671325"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2005-10-21","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We describe chemical separation procedure for the determination of Ra-226 in natural water samples with sector field ICP-MS. The proposed procedure is based on the combination of ion exchange and extraction chromatographic resins for preconcentration and separation of Ra from aqueous samples.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"Asia-Pacific Symposium on Radiochemistry (APSORC-05)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tolmachev, Sergei"}],"nameIdentifiers":[{"nameIdentifier":"671323","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tagami, Keiko"}],"nameIdentifiers":[{"nameIdentifier":"671324","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchida, Shigeo"}],"nameIdentifiers":[{"nameIdentifier":"671325","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tolmachev Sergei","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"671326","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上 恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"671327","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"671328","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"226Ra determination in Japanese river waters by sector field ICP-MS","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"226Ra determination in Japanese river waters by sector field ICP-MS"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-06-07"},"publish_date":"2006-06-07","publish_status":"0","recid":"68383","relation_version_is_last":true,"title":["226Ra determination in Japanese river waters by sector field ICP-MS"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:26:45.586557+00:00"}