{"created":"2023-05-15T14:49:48.571179+00:00","id":68192,"links":{},"metadata":{"_buckets":{"deposit":"8e6e3172-dda3-44c3-9e79-f8e8faf96dd2"},"_deposit":{"created_by":1,"id":"68192","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"68192"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00068192","sets":["10:28"]},"author_link":["669516","669506","669512","669515","669513","669518","669505","669519","669507","669510","669511","669514","669508","669517","669504","669509"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2005-10-01","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[目的]脳内の神経活動部位を推定するための、BOLD信号は血流(CBF)や血液量(CBV)、酸素代謝率などにも依存しており、神経活動をダイレクトに反映していない。我々は、正確なBOLDおよびCBF、CBVを測定し、神経活動と血管変化の動的な相関関係を知るために、2種類のシーケンスを用いてfMRIか大寺のデータを収集し、BOLD・CBF・CBV測定技術の最適化を行ったので報告する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第33回日本磁気共鳴医学会大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"富安, もよこ"}],"nameIdentifiers":[{"nameIdentifier":"669504","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠, 隆行"}],"nameIdentifiers":[{"nameIdentifier":"669505","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Wong, Eric C."}],"nameIdentifiers":[{"nameIdentifier":"669506","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柏倉, 健一"}],"nameIdentifiers":[{"nameIdentifier":"669507","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平野, 好幸"}],"nameIdentifiers":[{"nameIdentifier":"669508","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野中, 博意"}],"nameIdentifiers":[{"nameIdentifier":"669509","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須原, 哲也"}],"nameIdentifiers":[{"nameIdentifier":"669510","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平, 博夫"}],"nameIdentifiers":[{"nameIdentifier":"669511","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"その他"}],"nameIdentifiers":[{"nameIdentifier":"669512","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"富安 もよこ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669513","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠 隆行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669514","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柏倉 健一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669515","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平野 好幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669516","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野中 博意","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669517","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須原 哲也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669518","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平 博夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669519","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"3TにおけるBOLD・血流同時測定法(QUIPSS)および血液量測定法(VASO)の最適化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"3TにおけるBOLD・血流同時測定法(QUIPSS)および血液量測定法(VASO)の最適化"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-10-12"},"publish_date":"2005-10-12","publish_status":"0","recid":"68192","relation_version_is_last":true,"title":["3TにおけるBOLD・血流同時測定法(QUIPSS)および血液量測定法(VASO)の最適化"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:29:01.041800+00:00"}