{"created":"2023-05-15T14:49:48.484413+00:00","id":68190,"links":{},"metadata":{"_buckets":{"deposit":"e54414e6-39ad-4090-92ce-990aa928c3a9"},"_deposit":{"created_by":1,"id":"68190","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"68190"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00068190","sets":["10:28"]},"author_link":["669488","669487","669484","669482","669489","669491","669492","669481","669485","669486","669490","669483"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2005-10-01","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[目的]3TのMRI装置でのdiffusion weighted images (DWI)の撮像は、1.5T装置と比べてS/N比の向上や撮像時間の短縮など、DWIの画質改善に有利である。その一方で、信号収集にEPI法を使用した場合などには、長いTEによる磁化率効果の増大に伴う信号の低下や、画像の歪みが問題となる。そのため、近年その手法が実用段階になりつつあるparallel imaging法を用いたEPI-DWI撮像について、3Tと1.5TのMRI装置で比較検討を行った。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第33回日本磁気共鳴医学会大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"秋根, 良英"}],"nameIdentifiers":[{"nameIdentifier":"669481","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"太田, 深秀"}],"nameIdentifiers":[{"nameIdentifier":"669482","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森本, 卓哉"}],"nameIdentifiers":[{"nameIdentifier":"669483","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠, 隆行"}],"nameIdentifiers":[{"nameIdentifier":"669484","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須原, 哲也"}],"nameIdentifiers":[{"nameIdentifier":"669485","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平, 博夫"}],"nameIdentifiers":[{"nameIdentifier":"669486","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"秋根 良英","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669487","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"太田 深秀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669488","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森本 卓哉","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669489","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠 隆行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669490","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須原 哲也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669491","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平 博夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669492","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"3Tと1.5Tの臨床用MRI装置におけるdiffusion weighted imagesの比較検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"3Tと1.5Tの臨床用MRI装置におけるdiffusion weighted imagesの比較検討"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-10-12"},"publish_date":"2005-10-12","publish_status":"0","recid":"68190","relation_version_is_last":true,"title":["3Tと1.5Tの臨床用MRI装置におけるdiffusion weighted imagesの比較検討"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:29:02.552444+00:00"}