{"created":"2023-05-15T14:49:47.469538+00:00","id":68167,"links":{},"metadata":{"_buckets":{"deposit":"a1b2b87a-45c8-4904-a6fe-7192f09dd6da"},"_deposit":{"created_by":1,"id":"68167","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"68167"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00068167","sets":["10:28"]},"author_link":["669314","669315"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2005-09-16","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A low-energy ion deceleration system has been designed and installed in a beam-injection line at the NIRS-930 cyclotron. An advantage of this system, with utilized to the injection line, is to that it allows high-current ion-beam extraction from an ECR-ion source, because it can be operated with a large potential difference between the source and the extractor. The deceleration system is operated at a negative DC-voltage of around -10 kV, which is applied to the extractor and reduced to the ground potential by the decelerator. An electric field in the deceleration system was carefully designed by using a 3-dimensional field simulator. About a five-times intensity increase has been obtained for a 12C4+ beam at the cyclotron exit, as compared with the case where the new system is not used. Design studies of the decelerator as well as the result of a beam test are presented.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第11回イオン源国際会議(ICIS−05)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Honma, Toshihiro"}],"nameIdentifiers":[{"nameIdentifier":"669314","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"本間 壽廣","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"669315","nameIdentifierScheme":"WEKO"}]}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Low-energy Ion Decelerator for an External injection line at the NIRS-930 Cyclotron","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Low-energy Ion Decelerator for an External injection line at the NIRS-930 Cyclotron"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-09-27"},"publish_date":"2005-09-27","publish_status":"0","recid":"68167","relation_version_is_last":true,"title":["Low-energy Ion Decelerator for an External injection line at the NIRS-930 Cyclotron"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:29:19.522536+00:00"}