{"created":"2023-05-15T14:49:42.431100+00:00","id":68058,"links":{},"metadata":{"_buckets":{"deposit":"dda8c79e-4173-4648-aa70-1adc66e32523"},"_deposit":{"created_by":1,"id":"68058","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"68058"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00068058","sets":["10:28"]},"author_link":["668424","668425"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2005-05-20","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A compact injector consisting of a Radio Frequency Quadrupole (RFQ) linac and Interdigital H-mode Drift Tube Linac (IH-DTL) for medical accelerators was designed. A model cavity of IH-DTL was constructed and electric field distributions were measured. The measured distributions were compared with those calculated by a three dimensional field solver. With the comparison, accuracy of the solver was discussed. The RFQ linac has been constructed. The final design of IH-DTL is in progress. Construction of the entire compact injector will be completed by the end of this year, and a beam test will be performed.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"Particle Accelerator Conference (PAC05)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Iwata, Yoshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"668424","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩田 佳之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"668425","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Alternating-Phase-Focused Linac with Interdigital H-mode structure for medical injector","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Alternating-Phase-Focused Linac with Interdigital H-mode structure for medical injector"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-05-24"},"publish_date":"2005-05-24","publish_status":"0","recid":"68058","relation_version_is_last":true,"title":["Alternating-Phase-Focused Linac with Interdigital H-mode structure for medical injector"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:30:34.369231+00:00"}