{"created":"2023-05-15T14:49:32.323893+00:00","id":67832,"links":{},"metadata":{"_buckets":{"deposit":"0b683272-9daf-47c3-90a5-04b5fa7ddb7e"},"_deposit":{"created_by":1,"id":"67832","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"67832"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00067832","sets":["10:28"]},"author_link":["666462","666463"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2004-07-09","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A preliminary design of a compact heavy-ion injector for medical synchrotrons was presented. The compact injector consists of the Radio-Frequency-Quadrupole (RFQ) linac and Interdigital H-mode (IH) Drift-Tube-Linac (DTL). For the IH-DTL, Alternating-Phase-Focusing (APF) method will be applied. The electric field distribution of the IH cavity was calculated with a three-dimensional electromagnetic field solver and used for the simulations on the beam dynamics. By performing iterative calculations of the electric field and beam dynamics, the satisfactory emittance and acceptance were obtained. The compact injector will be constructed, and their beam test will be performed by the end of FY2005.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"9th European Particle Accelerator Conference (EPAC04)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Iwata, Yoshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"666462","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩田 佳之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"666463","nameIdentifierScheme":"WEKO"}]}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Alternating-phase-focused linac for an injector of medical synchrotrons","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Alternating-phase-focused linac for an injector of medical synchrotrons"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2004-07-12"},"publish_date":"2004-07-12","publish_status":"0","recid":"67832","relation_version_is_last":true,"title":["Alternating-phase-focused linac for an injector of medical synchrotrons"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:33:13.161644+00:00"}