{"created":"2023-05-15T14:49:15.070021+00:00","id":67453,"links":{},"metadata":{"_buckets":{"deposit":"89541e2e-954f-4e9d-ad62-220af1223d6d"},"_deposit":{"created_by":1,"id":"67453","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"67453"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00067453","sets":["10:28"]},"author_link":["663049","663047","663046","663045","663044","663050","663048","663051","663052"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2003-08-29","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Even though range calculation in treatment planning is crucial for charged particle therapy, the available methods to obtain relationship between effective density and CT number had been either inaccurate or too complicated. We therefore developed a simple and accurate method, the polybinary calibration, for the standardization purpose.\nThe standardization of CT calibration method has been made. Though the method might not be the final, any improvement will be handled within the established standardization system for charged particle therapy in Japan.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"World Congress on Medical Physics and Biomedical Engineering","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kanematsu, Nobuyuki"}],"nameIdentifiers":[{"nameIdentifier":"663044","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"663045","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Minohara, Shinichi"}],"nameIdentifiers":[{"nameIdentifier":"663046","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Endo, Masahiro"}],"nameIdentifiers":[{"nameIdentifier":"663047","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Asaskura, Hiroshi"}],"nameIdentifiers":[{"nameIdentifier":"663048","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"兼松 伸幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"663049","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"663050","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"蓑原 伸一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"663051","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"遠藤 真広","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"663052","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Standardization of CT Calibration Method for Charged Particle Therapy in Japan","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Standardization of CT Calibration Method for Charged Particle Therapy in Japan"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-09-01"},"publish_date":"2003-09-01","publish_status":"0","recid":"67453","relation_version_is_last":true,"title":["Standardization of CT Calibration Method for Charged Particle Therapy in Japan"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:37:33.811316+00:00"}