@misc{oai:repo.qst.go.jp:00067276, author = {Koguchi, Yasuhiro and Tsuruta, Takao and Yasuda, Nakahiro and Yamamoto, Mikio and 小口 靖弘 and 鶴田 隆雄 and 安田 仲宏 and 山本 幹男}, month = {Oct}, note = {Diallyl phthalate (DAP, C14H14O4), allyl diglycol carbonate (CR-39, C12H18O7) and mixtures of DAP and CR-39 were cast into resin plates under same polymerizing conditions. The plates were irradiated with several kinds of ion accelerator. After irradiation, the plates were etched with an aqueous solution of KOH. After etching, enlarged ion tracks (etch-pits) on the plates were observed using an optical microscope. The etch-pits daimeter increases linearly with the etching time. At any given etching time, as the concentration of DAP increases the etch-pits become smaller for any given kind of ions. The is a possibility of dscriminating positively between the kinds of the ions., 第21回 固体検出器国際会議}, title = {Nuclear track detector with controllable sensitivity using DAP, CR-39 and its copolymers}, year = {2002} }