{"created":"2023-05-15T14:49:00.723978+00:00","id":67132,"links":{},"metadata":{"_buckets":{"deposit":"91a6f799-c1ba-4c8c-a816-0d6727ced346"},"_deposit":{"created_by":1,"id":"67132","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"67132"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00067132","sets":["10:29"]},"author_link":["659968","659971","659966","659965","659962","659964","659969","659970","659967","659963","659961"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-07-25","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"According to test of power supply for JT-60SA central solenoid, the voltage has frequency component. And there are insulations between conductors. Then conductor insulations may break due to resonance phenomenon. In this study, we created circuit simulation model for JT-60SA central solenoid and analyzed relative between voltage distribution and electrical property (conductivity and relative dielectric constant) of insulations. As a result, the effect of frequency component is small, hence the insulation can’t be damaged less than 5 kHz.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"電気学会 金属・セラミックス 超電導機器 合同研究会 ","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"目黒, 博嵩"}],"nameIdentifiers":[{"nameIdentifier":"659961","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"那須, 京介"}],"nameIdentifiers":[{"nameIdentifier":"659962","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"園田, 翔梧"}],"nameIdentifiers":[{"nameIdentifier":"659963","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村, 一也"}],"nameIdentifiers":[{"nameIdentifier":"659964","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高尾, 智明"}],"nameIdentifiers":[{"nameIdentifier":"659965","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村上, 陽之"}],"nameIdentifiers":[{"nameIdentifier":"659966","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"夏目, 恭平"}],"nameIdentifiers":[{"nameIdentifier":"659967","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"木津, 要"}],"nameIdentifiers":[{"nameIdentifier":"659968","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村上 陽之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"659969","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"夏目 恭平","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"659970","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"木津 要","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"659971","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"JT-60SA中心ソレノイドにおける電圧分布と絶縁材料の電気的特性との関係","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"JT-60SA中心ソレノイドにおける電圧分布と絶縁材料の電気的特性との関係"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-02-01"},"publish_date":"2019-02-01","publish_status":"0","recid":"67132","relation_version_is_last":true,"title":["JT-60SA中心ソレノイドにおける電圧分布と絶縁材料の電気的特性との関係"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:41:12.116609+00:00"}