{"created":"2023-05-15T14:48:58.915570+00:00","id":67091,"links":{},"metadata":{"_buckets":{"deposit":"ba8f6da5-cedc-4a56-a157-9f7d90a542db"},"_deposit":{"created_by":1,"id":"67091","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"67091"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00067091","sets":["10:29"]},"author_link":["659433","659440","659434","659437","659443","659446","659431","659441","659432","659435","659436","659439","659445","659444","659442","659438","659447"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2019-03-14","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"ガンマ線トラッキング検出器は、ゲルマニウム結晶から成るセグメント型のガンマ線検出器で、入射ガンマ線の位置とエネルギーの情報を同時に得ることができる。ガンマ線トラッキング検出器の性能を評価するため、ニュースバル放射施設で稼働中の直線偏光をもつレーザーコンプトンガンマ線を用いて測定を行った。本講演では、実験方法及び測定結果について報告する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本物理学会年会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"甲田, 旭"}],"nameIdentifiers":[{"nameIdentifier":"659431","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本, 康嵩"}],"nameIdentifiers":[{"nameIdentifier":"659432","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"青井, 考"}],"nameIdentifiers":[{"nameIdentifier":"659433","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"井手口, 栄治"}],"nameIdentifiers":[{"nameIdentifier":"659434","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kumar, Raju M."}],"nameIdentifiers":[{"nameIdentifier":"659435","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Thi, Ha Hoang"}],"nameIdentifiers":[{"nameIdentifier":"659436","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Thanh, Pham Tung"}],"nameIdentifiers":[{"nameIdentifier":"659437","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"嶋, 達志"}],"nameIdentifiers":[{"nameIdentifier":"659438","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮本, 修治"}],"nameIdentifiers":[{"nameIdentifier":"659439","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"静間, 俊行"}],"nameIdentifiers":[{"nameIdentifier":"659440","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Topi, Benjamin Viljamaa"}],"nameIdentifiers":[{"nameIdentifier":"659441","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Wimmer, Kathrin"}],"nameIdentifiers":[{"nameIdentifier":"659442","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Doornenbal, Pieter"}],"nameIdentifiers":[{"nameIdentifier":"659443","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Liliana, Cortes Martha"}],"nameIdentifiers":[{"nameIdentifier":"659444","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今井, 伸明"}],"nameIdentifiers":[{"nameIdentifier":"659445","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hwang, Jongwon"}],"nameIdentifiers":[{"nameIdentifier":"659446","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"静間 俊行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"659447","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"ガンマ線トラッキング検出器の開発と性能評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ガンマ線トラッキング検出器の開発と性能評価"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-01-16"},"publish_date":"2019-01-16","publish_status":"0","recid":"67091","relation_version_is_last":true,"title":["ガンマ線トラッキング検出器の開発と性能評価"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:41:37.466519+00:00"}