{"created":"2023-05-15T14:48:58.775901+00:00","id":67088,"links":{},"metadata":{"_buckets":{"deposit":"ddfc92fc-011c-4714-ae44-bd9f8b5cc71e"},"_deposit":{"created_by":1,"id":"67088","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"67088"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00067088","sets":["10:29"]},"author_link":["659404","659399","659402","659401","659397","659406","659403","659396","659398","659408","659400","659407","659409","659405"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-09-15","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"重要な核医学診断法であるTc-99m/SPECTに代わる診断法として、Tc-95,Tc-96とコンプトンカメラ撮像の組み合わせの検討を行った。これらテクネチウム同位体はTc-99mと違い高いエネルギーのガンマ線を放出するため従来の検出法であるSPECTには適さない。500から800 keVの高いエネルギーのガンマ線放出核種であるTc-95およびTc-96の検出としてコンプトンカメラ(Electron Tracking Compton Camera)に着目し、ETCCによるTc-95の撮像実験を通して核医学診断法開発に向けた基礎研究を行った。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第116回日本医学物理学会学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"株木重人"}],"nameIdentifiers":[{"nameIdentifier":"659396","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"初川雄一"}],"nameIdentifiers":[{"nameIdentifier":"659397","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高木彰"}],"nameIdentifiers":[{"nameIdentifier":"659398","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村圭吾"}],"nameIdentifiers":[{"nameIdentifier":"659399","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"櫛田淳子"}],"nameIdentifiers":[{"nameIdentifier":"659400","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"塚田和明"}],"nameIdentifiers":[{"nameIdentifier":"659401","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"浅井雅人"}],"nameIdentifiers":[{"nameIdentifier":"659402","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"豊嶋厚史"}],"nameIdentifiers":[{"nameIdentifier":"659403","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高田淳史"}],"nameIdentifiers":[{"nameIdentifier":"659404","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水本哲也"}],"nameIdentifiers":[{"nameIdentifier":"659405","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"園田信也"}],"nameIdentifiers":[{"nameIdentifier":"659406","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西嶋恭司"}],"nameIdentifiers":[{"nameIdentifier":"659407","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷森達"}],"nameIdentifiers":[{"nameIdentifier":"659408","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"初川 雄一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"659409","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"電子飛跡検出型コンプトンカメラを用いた95-Tcの画像化試験","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"電子飛跡検出型コンプトンカメラを用いた95-Tcの画像化試験"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-01-15"},"publish_date":"2019-01-15","publish_status":"0","recid":"67088","relation_version_is_last":true,"title":["電子飛跡検出型コンプトンカメラを用いた95-Tcの画像化試験"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:41:39.411163+00:00"}