{"created":"2023-05-15T14:48:48.324391+00:00","id":66854,"links":{},"metadata":{"_buckets":{"deposit":"d8ae2c40-6d23-43f6-aa09-58b10bda8656"},"_deposit":{"created_by":1,"id":"66854","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"66854"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00066854","sets":["10:29"]},"author_link":["657350","657352","657353","657351","657354","657349"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-07-06","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"α放射性RIであるハロゲン元素アスタチン211Atは、癌に対するRI内用療法への適用が期待されている。この211Atを研究開発に利用するための乾式蒸留に基づく簡易な211Atトレーサー溶液調整法を開発した。高崎研TIARAにおいて211Atを製造し、溶液調整に用いた。この溶液調整法では、約50分の操作時間で約1.6mLの4種類の溶媒で30-80%の化学収率で高純度なトレーサー溶液が調整できた。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第55回アイソトープ・放射線研究発表会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"西中, 一朗"}],"nameIdentifiers":[{"nameIdentifier":"657349","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石岡, 典子"}],"nameIdentifiers":[{"nameIdentifier":"657350","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"渡辺, 茂樹"}],"nameIdentifiers":[{"nameIdentifier":"657351","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西中 一朗","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"657352","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石岡 典子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"657353","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"渡辺 茂樹","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"657354","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"乾式蒸留に基づく簡易At-211トレーサー溶液調整","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"乾式蒸留に基づく簡易At-211トレーサー溶液調整"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-07-18"},"publish_date":"2018-07-18","publish_status":"0","recid":"66854","relation_version_is_last":true,"title":["乾式蒸留に基づく簡易At-211トレーサー溶液調整"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:44:10.551422+00:00"}