{"created":"2023-05-15T14:48:39.150489+00:00","id":66652,"links":{},"metadata":{"_buckets":{"deposit":"d3a6168b-7698-4cde-b937-ab0fc59b8dff"},"_deposit":{"created_by":1,"id":"66652","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"66652"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00066652","sets":["10:29"]},"author_link":["655456","655451","655446","655455","655448","655454","655449","655447","655450","655445","655453","655452"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-03-19","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"超短パルス高出力レーザーとガスを相互作用させるとレーザー航跡場が生成できることが知られている。レーザープラズマ電子をこの航跡場で加速し、高エネルギー電子を発生させる研究が世界中で試みられている。 \nさらに近年、レーザープラズマ電子が航跡場中を進行する際、進行方向にベータトロンX線と呼ばれる高エネルギーの白色X線が生成される事が明らかになってきた。このベータトロンX線のエネルギー分布計測は、通常フィルター法で行われている。しかしこの方法ではエネルギー分解能があまり高くないため、X線エネルギー分布を詳細に議論できない問題があった。\nそこで発表者等は高エネルギー分解能でのベータトロンX線計測を目指しX線分光器を開発した。本分光器ではターゲットから放射されたベータトロンX線の一部(Bragg条件を満足したX線)を湾曲結晶でBragg反射した後、下流のX線計測器で計測される。湾曲結晶にGe(220)単結晶を用いており、30 - 100keVの高エネルギーX線を計測可能である。\nさらに高フルエンスのX線発生装置を利用し、本装置の分光特性を確認している。X線発生装置からはW K殻X線が放射されるが、このW KaX線(59.3, 58.0 keV)のピークを本分光器で観測できる事が確認された。今回の発表ではこの分光器の性能に関して、より詳細に議論する予定である。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第65回 応用物理学会 春季学術講演会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"林, 由紀雄"}],"nameIdentifiers":[{"nameIdentifier":"655445","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小瀧, 秀行"}],"nameIdentifiers":[{"nameIdentifier":"655446","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森, 道昭"}],"nameIdentifiers":[{"nameIdentifier":"655447","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"黄, 開"}],"nameIdentifiers":[{"nameIdentifier":"655448","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中新, 信彦"}],"nameIdentifiers":[{"nameIdentifier":"655449","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神門, 正城"}],"nameIdentifiers":[{"nameIdentifier":"655450","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"林 由紀雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"655451","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小瀧 秀行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"655452","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森 道昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"655453","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"黄 開","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"655454","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中新 信彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"655455","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神門 正城","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"655456","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"ベータトロンX線計測用 X線分光器の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ベータトロンX線計測用 X線分光器の開発"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-03-15"},"publish_date":"2018-03-15","publish_status":"0","recid":"66652","relation_version_is_last":true,"title":["ベータトロンX線計測用 X線分光器の開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:46:31.678356+00:00"}