{"created":"2023-05-15T14:48:26.170815+00:00","id":66363,"links":{},"metadata":{"_buckets":{"deposit":"04fd6223-2898-4cd1-aa2a-4f4d27c1ccf2"},"_deposit":{"created_by":1,"id":"66363","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"66363"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00066363","sets":["10:29"]},"author_link":["652951","652955","652947","652956","652953","652949","652950","652957","652948","652954","652952"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-06-28","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"CT撮影による被ばく線量評価システムWAZA-ARIは平成24年12月に試験運用を開始し、その後大幅に機能を改良しWAZA-ARIv2として平成27年1月より本格的な運用を開始した。これまでに計算に選択できるCTモデルの拡充を図るとともに、講演・セミナーなどを広く開催し多くのユーザにWAZA-ARIv2の利用を呼びかけた。現在ユーザ数は1000名を超え、非常に多くの病院や研究・教育機関にて利用されている。現在、開発グループでは各施設内の被ばく線量管理ツールからの接続に対し自動的に被ばく線量を計算し、結果を送信する機能の開発を進めている。この機能実装により、簡便にCT撮影時の線量計算結果を提供するとともに広く撮影条件の実態データの収集を行っていく予定である。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本保健物理学会第50回研究発表会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"古場, 裕介"}],"nameIdentifiers":[{"nameIdentifier":"652947","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"奥田, 保男"}],"nameIdentifiers":[{"nameIdentifier":"652948","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仲田, 佳広"}],"nameIdentifiers":[{"nameIdentifier":"652949","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽, 恵一"}],"nameIdentifiers":[{"nameIdentifier":"652950","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神田, 玲子"}],"nameIdentifiers":[{"nameIdentifier":"652951","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"al., et"}],"nameIdentifiers":[{"nameIdentifier":"652952","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古場 裕介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"652953","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"奥田 保男","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"652954","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仲田 佳広","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"652955","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽 恵一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"652956","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神田 玲子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"652957","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"CT撮影による被ばく線量評価システムWAZA-ARI v2の現状と今後の展望","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"CT撮影による被ばく線量評価システムWAZA-ARI v2の現状と今後の展望"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-07-04"},"publish_date":"2017-07-04","publish_status":"0","recid":"66363","relation_version_is_last":true,"title":["CT撮影による被ばく線量評価システムWAZA-ARI v2の現状と今後の展望"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:49:48.166767+00:00"}