{"created":"2023-05-15T14:48:16.065048+00:00","id":66142,"links":{},"metadata":{"_buckets":{"deposit":"4b51290b-0409-4e81-abad-25cda893d826"},"_deposit":{"created_by":1,"id":"66142","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"66142"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00066142","sets":["10:29"]},"author_link":["776176","776173","776178","776165","776163","776170","776169","776174","776161","776166","776167","776177","776171","776172","776162","776175","776164","776168"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-03-03","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose:\nThere is an emerging demand for dedicated brain PET for the study and diagnosis of neurological disorders such as dementia. We have proposed a helmet PET geometry with add-on detector for high sensitivity, high resolution and low cost brain PET. Our first prototype had the add-on detector at chin position (helmet-chin PET). However, the gantry design gave oppressive feeling to the patient and moving part of chin detector was not convenient for the patient setup. We have shown by simulation that the add-on detectors covering the patient head is equivalently effective. In this study, we developed the helmet-neck PET for improving the convenience.\nMethods and Materials:\nWe developed the helmet PET prototype using 54 four-layer depth-of-interaction detectors with 16×16×4 array of 2.8×2.8×7.5 mm3 Zr-doped GSO crystals. In the prototype, 47 detectors were arrangement in a hemisphere, and seven detectors were placed as an add-on detector. We compared helmet-chin PET and helmet-neck PET in terms of the effect of the add-on detector for increasing the sensitivity.\nResults:\nThe sensitivity measured with a hemispherical phantom for the brain region was increased by 12% in the helmet-chin PET and by 19% in the helmet-neck PET compared with the geometry without add-on detector. This is because the arrangement of the detector at chin position required larger margin for designing gantry, in which detector position became farther than the case of neck position.\nConclusion:\nThe helmet-neck PET has promising performance for high sensitivity brain imaging and improved convenience for patient studies.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"European Congress of Radiology (ECR) 2017","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田島, 英朗"}],"nameIdentifiers":[{"nameIdentifier":"776161","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田, 英治"}],"nameIdentifiers":[{"nameIdentifier":"776162","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩男, 悠真"}],"nameIdentifiers":[{"nameIdentifier":"776163","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"脇坂, 秀克"}],"nameIdentifiers":[{"nameIdentifier":"776164","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高堂, 裕平"}],"nameIdentifiers":[{"nameIdentifier":"776165","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"関, 千江"}],"nameIdentifiers":[{"nameIdentifier":"776166","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須原, 哲也"}],"nameIdentifiers":[{"nameIdentifier":"776167","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山下, 大地"}],"nameIdentifiers":[{"nameIdentifier":"776168","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山谷, 泰賀"}],"nameIdentifiers":[{"nameIdentifier":"776169","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tashima, Hideaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776170","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshida, Eiji","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776171","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iwao, Yuma","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776172","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Wakizaka, Hidekatsu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776173","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takado, Yuhei","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776174","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Seki, Chie","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776175","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suhara, Tetsuya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776176","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamashita, Taichi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776177","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaya, Taiga","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776178","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Development of the helmet-neck PET prototype for high sensitivity brain imaging","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of the helmet-neck PET prototype for high sensitivity brain imaging"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-12-01"},"publish_date":"2016-12-01","publish_status":"0","recid":"66142","relation_version_is_last":true,"title":["Development of the helmet-neck PET prototype for high sensitivity brain imaging"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:21:07.301082+00:00"}