{"created":"2023-05-15T14:48:06.784835+00:00","id":65938,"links":{},"metadata":{"_buckets":{"deposit":"63e6269e-6d77-4f83-88c5-0ac64d2083b3"},"_deposit":{"created_by":1,"id":"65938","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"65938"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00065938","sets":["10:29"]},"author_link":["649511","649510","649506","649509","649505","649508","649507","649512"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2016-08-10","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"重粒子線治療において,PET装置で照射野をリアルタイムに検証する技術を実現するために,Isotope Separation On-Line (ISOL)法により11CビームをHIMACシンクロトロンから供給することを計画している.この方法では,小型サイクロトロンによるプロトン照射で生成された11C分子をイオン化して加速する.このイオン化のプロセスでは,まず1価イオンを生成し不要な同位体を分離した後に,目的の11C+イオンをEBISイオン源に入射して荷電増幅を行う.このISOLシステムに用いる低エネルギー電子ビーム1価イオン源の開発を現在進めている.限られた生成量の11C分子から,治療に要求される量の11Cイオンを生成するためには,1価イオン源は少なくとも~0.1%のC+イオンの生成効率を達成しなければならない.このイオン化効率を得るためには,イオン源内ドリフトチューブにおける電子ビーム実効電流量が100 mA以上必要であると見積もられている.この実効電流量を達成するために,イオン源内電極構造の最適化を行った.この最適化は,新たに開発したPIC (Particle in Cell) 法を用いた3次元粒子計算コードにより,電子ビームの軌道を解析することで行った.本発表では,これらの計算結果と実験結果の比較を示すと共に,最適化されたイオン源の性能を議論する.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第13回日本加速器学会年会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"片桐, 健"}],"nameIdentifiers":[{"nameIdentifier":"649505","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田, 章"}],"nameIdentifiers":[{"nameIdentifier":"649506","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"涌井, 崇志"}],"nameIdentifiers":[{"nameIdentifier":"649507","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田, 耕司"}],"nameIdentifiers":[{"nameIdentifier":"649508","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"片桐 健","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"649509","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 章","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"649510","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"涌井 崇志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"649511","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"649512","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"3次元PIC解析による重粒子線治療ISOLシステム用1価イオン源の最適化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"3次元PIC解析による重粒子線治療ISOLシステム用1価イオン源の最適化"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-08-15"},"publish_date":"2016-08-15","publish_status":"0","recid":"65938","relation_version_is_last":true,"title":["3次元PIC解析による重粒子線治療ISOLシステム用1価イオン源の最適化"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:54:37.676024+00:00"}