{"created":"2023-05-15T14:48:06.608661+00:00","id":65934,"links":{},"metadata":{"_buckets":{"deposit":"2f7773bf-2a38-40db-bc69-1f3e76cd2b00"},"_deposit":{"created_by":1,"id":"65934","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"65934"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00065934","sets":["10:29"]},"author_link":["649471","649469","649468","649470"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2016-05-26","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"電子顕微鏡を用いた元素分析、構造解析、状態分析などの目的でエネ ルギー分散形分光器(EDS)、波長分散形分光器(WDS)など多くの分光器 が開発されてきた。しかしながら、リチウム等の軽元素の分析に必要な軟 X線領域において実用的な電子顕微鏡用分光器は存在しなかった。そこで、不等間隔溝収差補正型回折格子と高感度X線CCDカメラを組み合わせることにより、高エネルギー分解能を実現する電子顕微鏡用軟X線分光器システムを開発した。この装置の特長はEDS同様にパラレル検出可能で、かつWDSが持つエネルギー分解能を超える0.3eV (Fermi端 Al-L基準) の高エネルギー分解能分析が 50eV~4keVの広いエネルギー領域で可能である等である。この分光器システムでは回折格子や検出器(CCD)を動かさずに広いエネルギー領域のスペ クトルを同時に測定できる。しかも高エネルギー分解能であるので、状態分析マップの収集が可能である。この装置のボロンを含む核燃料デブリ分析、リチウムイオン電池開発、先端合金開発等への応用について紹介する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"平成 28年度日本分光学会国際シンポジウム・年次講演会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小池, 雅人"}],"nameIdentifiers":[{"nameIdentifier":"649468","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"寺内正己"}],"nameIdentifiers":[{"nameIdentifier":"649469","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高橋秀之"}],"nameIdentifiers":[{"nameIdentifier":"649470","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小池 雅人","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"649471","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"電子顕微鏡用軟 X線分光器の開発と実用化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"電子顕微鏡用軟 X線分光器の開発と実用化"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-07-28"},"publish_date":"2016-07-28","publish_status":"0","recid":"65934","relation_version_is_last":true,"title":["電子顕微鏡用軟 X線分光器の開発と実用化"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:54:39.688673+00:00"}