{"created":"2023-05-15T14:48:05.162090+00:00","id":65902,"links":{},"metadata":{"_buckets":{"deposit":"896e23ff-b6cb-49b3-9217-ac59fc589cd7"},"_deposit":{"created_by":1,"id":"65902","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"65902"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00065902","sets":["10:29"]},"author_link":["776280","776276","776272","776273","776271","776275","776279","776281","776277","776278","776274","776282"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2016-04-16","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"目的\n放射線医学総合研究所の独自アイディアであるヘルメットPETは,従来の円筒形のジオメトリの頭部PETに比べ,高い感度と開放性を併せ持つ.PET-CTのような一体型の装置と異なり,本装置は小型化を実現するため,CT装置を含まない独立した装置であり,吸収補正に際して特別の配慮が必要となる.本研究では,μマップの取得に際し,CTデータとの位置合わせを行う手法についての検討を行った.\n方法\nヘルメットPETで撮像されたデータに対し,始めに吸収補正無しの再構成を行い,初期PETイメージを得る.別途撮像したCTデータから生成したμマップとのキャリブレーションを行い患者の位置を調整した.具体的には,初期PETイメージとμマップを重ね合わせて表示し,平行移動,回転の6パラメータを任意に調整可能なシステムを構築した.パラメータの調整法については検討中であり,今回は目視にて両データの頭部位置の重なり具合を確認しつつパラメータの調整を行った.位置合わせを行ったμマップを用いて,PETデータの再構成を行い,最終的な出力を得た.\n結果\nヘルメットPETを用いた頭部ボランティア撮像を行った.提案システムよる吸収補正を実施したPETイメージの再構成を行い,いずれも良好な結果が取得できた.\n考察と結論\n独立したヘルメットPETとCTデータ間において,マニュアルで位置合わせを行う手法を確立した.\n今後は,位置合わせパラメータの調整法について検討を進めるとともに,MRIベースのμマップ生成法,またはレンジセンサによる患者のサーフェスモデルを用いたアトラスベースの手法について検討を進め,被ばく量の低減や,コストの削減といった要素を追求していきたい.\n","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第111回日本医学物理学会学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩男, 悠真"}],"nameIdentifiers":[{"nameIdentifier":"776271","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田島, 英朗"}],"nameIdentifiers":[{"nameIdentifier":"776272","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田, 英次"}],"nameIdentifiers":[{"nameIdentifier":"776273","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐野, ひろみ"}],"nameIdentifiers":[{"nameIdentifier":"776274","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"木村, 泰之"}],"nameIdentifiers":[{"nameIdentifier":"776275","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山谷, 泰賀"}],"nameIdentifiers":[{"nameIdentifier":"776276","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iwao, Yuma","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776277","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tashima, Hideaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776278","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshida, Hidetsugu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776279","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sano, Hiromi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776280","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kimura, Yasuyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776281","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaya, Taiga","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"776282","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"CT画像を用いたヘルメットPET吸収補正法の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"CT画像を用いたヘルメットPET吸収補正法の開発"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-06-07"},"publish_date":"2016-06-07","publish_status":"0","recid":"65902","relation_version_is_last":true,"title":["CT画像を用いたヘルメットPET吸収補正法の開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:20:47.160535+00:00"}