{"created":"2023-05-15T14:47:54.338558+00:00","id":65658,"links":{},"metadata":{"_buckets":{"deposit":"cd1b7e18-5ba6-4d94-a945-739e93b8fdc4"},"_deposit":{"created_by":1,"id":"65658","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"65658"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00065658","sets":["10:29"]},"author_link":["646758","646764","646765","646763","646759","646760","646761","646762","646757"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2015-04-19","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"1.背景・目的\n近年,電離箱は小容量化,治療用照射装置は高線量率化の傾向にあり,また産業技術総合研究所では線種毎の標準供給が計画されている.そのため将来,現行の一体校正のままでは難しい局面を迎えるであろう.\n現在,医用原子力技術研究振興財団では電位計と電離箱の分離校正のJCSS登録事業者を目指している.欧米1,2)には既に分離校正があるが,日本では電位計の標準が確立されていない.電位計の常用参照標準は,製品評価技術基盤機構(NITE)発行のJCT-21007技術的要求事項適用指針(適用指針)3)の具備条件を満たせば良い.そこで適用指針に準拠し,電荷の絶対計測を可能とする標準電位計を組み立てた.\n2.方法\n電位計には適用指針の具備条件を満たす川口電機製作所製のMMAⅡ-17Eを,フィードバックキャパシタには同社製の空気キャパシタを用いた.またMMAⅡ-17Eの出力電圧はDMM(YOKOGAWA7562)で読み取った.これらの空気キャパシタ及びDMMは,適用指針のトレーサビリティ体系に従い,JCSS登録事業者によるJCSS校正を予め受けた.\n電位計の電位感度(入力電圧と出力電圧の関係)はDMM及び直流電圧発生装置(ADCMT6161)を用いて自己校正した.\nケーブルを含めた回路上の静電容量(内部容量)は,黒澤らの方法4)に倣い,空気キャパシタ及び直流電圧発生装置を用いて決定した.\n標準電位計の妥当性は,欧米の電位計校正1,2)に倣い,空気キャパシタ及び直流電圧により組み立てた電荷を計測し,理論値(Q=C×V)と比較することで検証した.\n3.結果・考察\n電位感度の自己校正値は,1~2ヶ月の校正頻度でも不確かさ0.011%として運用できることが分かった.\n内部容量は,電荷計測前に毎回決定すれば不確かさが0.01%未満になることが分かった.\n標準電位計による電荷計測値は,その不確かさ0.049%(k=1)の範囲内で理論値と一致した.自己校正及び決定作業を含め,標準電位計の妥当性が示された.\n4.結論\nNITEの適用指針に準拠して標準電位計を組み立てた ところ,その電荷計測値は不確かさの範囲内で理論値と一致した.この標準電位計は,ユーザ電位計を比較校正するための常用参照標準として使用できる.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第109 回日本医学物理学会学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"高瀬, 信宏"}],"nameIdentifiers":[{"nameIdentifier":"646757","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐方, 周防"}],"nameIdentifiers":[{"nameIdentifier":"646758","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水野, 秀之"}],"nameIdentifiers":[{"nameIdentifier":"646759","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福村, 明史"}],"nameIdentifiers":[{"nameIdentifier":"646760","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"al., et"}],"nameIdentifiers":[{"nameIdentifier":"646761","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高瀬 信宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646762","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐方 周防","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646763","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水野 秀之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646764","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福村 明史","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646765","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Development of a separated calibration system for electrometer and ionizing chamber (1): Standard electrometer","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a separated calibration system for electrometer and ionizing chamber (1): Standard electrometer"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-05-19"},"publish_date":"2015-05-19","publish_status":"0","recid":"65658","relation_version_is_last":true,"title":["Development of a separated calibration system for electrometer and ionizing chamber (1): Standard electrometer"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:57:41.530631+00:00"}