{"created":"2023-05-15T14:47:51.876008+00:00","id":65619,"links":{},"metadata":{"_buckets":{"deposit":"7a026b7e-1d4a-4137-9cf1-8782b3f82985"},"_deposit":{"created_by":1,"id":"65619","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"65619"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00065619","sets":["10:29"]},"author_link":["646295","646300","646305","646303","646306","646296","646304","646294","646302","646297","646301","646298","646299"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2015-03-30","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"これまでにポリイミド樹脂に対し重イオンを照射した研究がいくつか報告されている。本研究ではポリイミド樹脂であるUPILEX-RNを用いて、高閾値飛跡検出器としての応用可能性を探ることを目的とし,種々の重イオンを照射した。なお1.1 MeV/n のNeイオンを照射した試料ではエッチピットがエッチング処理の途中から生成していることが確認できた。この現象はポリイミド樹脂の一種であるUPILEX-S及びKaptonにおいても確認することができた。新しい試みとして走査型電子顕微鏡を用いて、UPILEX-RN, UPILEX-S及びKapton を対象として生成初期段階のエッチピットの観察及びエッチピット検出閾値の決定を行った。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第29回固体飛跡検出器研究会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"安田, 修一郎"}],"nameIdentifiers":[{"nameIdentifier":"646294","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"楠本, 多聞"}],"nameIdentifiers":[{"nameIdentifier":"646295","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小田, 啓二"}],"nameIdentifiers":[{"nameIdentifier":"646296","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小平, 聡"}],"nameIdentifiers":[{"nameIdentifier":"646297","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村, 尚"}],"nameIdentifiers":[{"nameIdentifier":"646298","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山内, 知也"}],"nameIdentifiers":[{"nameIdentifier":"646299","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"蔵岡, 孝治"}],"nameIdentifiers":[{"nameIdentifier":"646300","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安田 修一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646301","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"楠本 多聞","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646302","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小田 啓二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646303","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小平 聡","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646304","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646305","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山内 知也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"646306","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"高閾値飛跡検出器としてのポリイミド樹脂の研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高閾値飛跡検出器としてのポリイミド樹脂の研究"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-04-14"},"publish_date":"2015-04-14","publish_status":"0","recid":"65619","relation_version_is_last":true,"title":["高閾値飛跡検出器としてのポリイミド樹脂の研究"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:58:05.745112+00:00"}