{"created":"2023-05-15T14:47:41.115901+00:00","id":65381,"links":{},"metadata":{"_buckets":{"deposit":"012d555c-750e-42e6-89ef-dfbaf3c343e3"},"_deposit":{"created_by":1,"id":"65381","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"65381"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00065381","sets":["10:29"]},"author_link":["644108","644107"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2013-12-06","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The new developments at the HIMAC include a super-conducting carbon gantry, a new therapy area with three new treatment rooms and substantial enhancements to the synchrotron extraction system to enable energy variation through multiple flattops within a synchrotron cycle to match the characteristics of the gantry and three-dimensional raster scanning. The carbon gantry consists of ten combined-function superconducting magnets, allowing a very compact geometry. The length and the radius of the gantry are approximately 13 and 5.5 m, respectively, comparable to the dimensions of existing proton gantries. Furthermore, these superconducting magnets are designed for fast slewing of the magnetic field to follow the multiple flattop operation of the synchrotron. In this paper, the recent research and development of a superconducting rotating-gantry for carbon-ion therapy is presented.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"NIRS & MedAustron Joint Symposium on Carbon Ion Radiotherapy","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩田, 佳之"}],"nameIdentifiers":[{"nameIdentifier":"644107","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩田 佳之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"644108","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"R&D of Superconducting Rotating Gantry for Carbon Ion Radiotherapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"R&D of Superconducting Rotating Gantry for Carbon Ion Radiotherapy"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-12-09"},"publish_date":"2013-12-09","publish_status":"0","recid":"65381","relation_version_is_last":true,"title":["R&D of Superconducting Rotating Gantry for Carbon Ion Radiotherapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:00:45.529636+00:00"}