{"created":"2023-05-15T14:47:33.552430+00:00","id":65210,"links":{},"metadata":{"_buckets":{"deposit":"b64d37de-701c-4762-8ff7-79984f7b2a06"},"_deposit":{"created_by":1,"id":"65210","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"65210"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00065210","sets":["10:29"]},"author_link":["642459","642457","642458","642456","642455","642460"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2013-10-19","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【目的】 \n千葉市内の複数の医療機関における小児を対象にしたMDCTの撮影実態を調査し、放射線診療の最適化の目的で診断参考レベル(DRL)設定のための参考データを提供する。\n\\n【方法】\n調査施設は千葉市内の小児専門病院(3次救急)と総合病院2施設(2次救急)である。調査したCT装置はLightSpeed VCT64(GE)、AquilionM16(東芝)であり、調査対象期間は2005年から2012年までに検査をした小児(15歳未満)6,718件を対象とし、撮影条件、CTDIvol、DLPを参照した。頭部、胸部、腹部CTについて年齢ごと4グループに分け集計し、3/4値を各国DRLと比較した。\n\\n【結果考察】\n頭部CTDIは各年齢でICRP87のDRLと類似した傾向であった。胸部、腹部CTDIはICRPの値よりも1/3程度と低かった。10歳以上のグループで高い線量となっていた。これは12歳前後で成人用撮影条件を適用することが多いためである。一方、近年各国のDRLはICRPの値より低くなっており、本調査の頭部CTDIは全年齢にわたり平均1.5倍程度高い傾向にあったため、撮影線量最適化の必要があると考える。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第41回 日本放射線技術学会秋季学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"仲田, 佳広"}],"nameIdentifiers":[{"nameIdentifier":"642455","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"島田, 義也"}],"nameIdentifiers":[{"nameIdentifier":"642456","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽, 恵一"}],"nameIdentifiers":[{"nameIdentifier":"642457","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"その他"}],"nameIdentifiers":[{"nameIdentifier":"642458","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"島田 義也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"642459","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽 恵一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"642460","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"診断参考レベル( Dose Reference Level :DRL)設定の千葉市内における小児CT検査","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"診断参考レベル( Dose Reference Level :DRL)設定の千葉市内における小児CT検査"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-10-22"},"publish_date":"2013-10-22","publish_status":"0","recid":"65210","relation_version_is_last":true,"title":["診断参考レベル( Dose Reference Level :DRL)設定の千葉市内における小児CT検査"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:02:43.715973+00:00"}