{"created":"2023-05-15T14:47:23.128108+00:00","id":64975,"links":{},"metadata":{"_buckets":{"deposit":"28278e9d-1b4d-4e61-a977-3a53f135f0f1"},"_deposit":{"created_by":1,"id":"64975","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"64975"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00064975","sets":["10:29"]},"author_link":["640252","640260","640258","640251","640256","640261","640254","640257","640262","640259","640255","640253"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2013-04-14","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【背景・目的】我々のグループでは18 mm3のシンチレータ(LYSO)をレー\nザー加工によりセグメント化したクリスタルキューブ(X’tal cube)の開発を行って\nいる。相互作用位置は各面に4x4のSi-PM (MPPC)を貼り付けてアンガー計算により算\n出している。現在は全面(6面)にMPPCを取り付けて、つまり4x4x6面=96のMPPCの読\nみ出しを行っている。しかしPET検出器としての実用性の観点から、より少ない読み\n出しが望ましい。そこで検出面を2面まで減らした場合の相互作用位置の識別能につ\nいて調べた。【方法】2mm3 (9x9x9)、3mm3(6x6x6)にセグメ\nント化したX’tal cubeを用いて、それぞれ検出面を6,4,3,2面まで減らした場合のpe\nak-to-valley ratio (peak/valley)およびdistance-to-width ratio (distance/widt\nh)を調べた。Distance/widthは、あるセグメント列のプロファイルをとり、隣同士の\nピーク間の距離をガウスフィットで求めた幅で除したものである。セグメント列のプ\nロファイルはX,Y,Z方向全てにおいて検討した。【結果】3mm3にセグメン\nト化したX’tal cubeのおいては、2面に減らした場合でも各セグメントの応答の確認\nできた。peak/valleyは6面から2面に減らすことで、平均15から6.6に、distance/wid\nthは4.6から2.6に減少した。2mm3についてもpeak/valleyは6面から2面で\n、平均13から5.5に、distance/widthは4.6から2.4に減少したが、各セグメントの応\n答の確認はできた。また面数を減らすことで、X、Y、Z方向における識別能の非対称\n性が見られた。【結論】レーザー加工によって3mm3、2mm3に\nセグメント化したX’tal cubeの検出面を6面から、2面に減らしても、識別能は低下\nするが、各セグメントの応答は確認できた。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第105回日本医学物理学会学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"平野, 祥之"}],"nameIdentifiers":[{"nameIdentifier":"640251","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"稲玉, 直子"}],"nameIdentifiers":[{"nameIdentifier":"640252","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田, 英治"}],"nameIdentifiers":[{"nameIdentifier":"640253","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"錦戸, 文彦"}],"nameIdentifiers":[{"nameIdentifier":"640254","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村山, 秀雄"}],"nameIdentifiers":[{"nameIdentifier":"640255","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山谷, 泰賀"}],"nameIdentifiers":[{"nameIdentifier":"640256","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平野 祥之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"640257","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"稲玉 直子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"640258","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田 英治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"640259","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"錦戸 文彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"640260","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村山 秀雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"640261","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山谷 泰賀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"640262","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"レーザー加工によるPET用3次元放射線検出器クリスタルキューブの開発:受光面の最 適化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"レーザー加工によるPET用3次元放射線検出器クリスタルキューブの開発:受光面の最 適化"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-04-22"},"publish_date":"2013-04-22","publish_status":"0","recid":"64975","relation_version_is_last":true,"title":["レーザー加工によるPET用3次元放射線検出器クリスタルキューブの開発:受光面の最 適化"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:05:28.082573+00:00"}