{"created":"2023-05-15T14:47:01.676657+00:00","id":64503,"links":{},"metadata":{"_buckets":{"deposit":"be551a07-3254-42c7-94d7-8346b7ed50da"},"_deposit":{"created_by":1,"id":"64503","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"64503"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00064503","sets":["10:29"]},"author_link":["635831","635833","635830","635826","635828","635827","635829","635832"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2011-11-19","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[目的]\n子宮頸がんに対するハイリスクCTV(HR-CTV)線量の解析に腔内照射時に撮影したCT画像を用いる際、毎回のCT撮影の必要性について検討を行った。\n\\n[方法]\n2008年10月〜2010年10月に群馬大学で子宮頸癌に対して根治照射を行った61症例のうち、定型的な腔内照射(TandemとOvoidのみを使用しA点に6Gyの照射を4回)を行った28症例を対象とした。各腔内照射時に撮影されたCT画像を用いてHR-CTV D90を求めた。Contouringの際には初回の腔内照射直前のMRI画像を参照し、二人の放射線科医によるダブルチェックを行った。\n\\n[結果]\nHR-CTV D90の平均値(+-SD)は腔内照射1回目:6.1Gy(+-1.3)、2回目:6.6Gy(+-1.0)、3回目:7.0Gy(+-1.0)、4回目:7.1Gy(+-1.0)であった。腔内照射2回目の値を1回目と3回目の値で平均で近似したときの平均値は6.6Gy(+-1.0)であり、実測値とのピアソンの相関係数はr=0.944と強い相関が認められた。また腔内照射4回目の値を3回目の値で近似したときのピアソンの相関係数はr=0.991であった。\n\\n[結論]\nA点線量を固定した腔内照射のHR-CTV D90は3回目まで増加傾向を示し、1回目と3回目の腔内照射時のCT撮影により、2回目と4回目のHR-CTV D90は高い精度で近似された。よって、特に1回目と3回目のCT撮影が重要であると考えられた。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本放射線腫瘍学会 第24回学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大久保, 悠"}],"nameIdentifiers":[{"nameIdentifier":"635826","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大野, 達也"}],"nameIdentifiers":[{"nameIdentifier":"635827","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田, 真永"}],"nameIdentifiers":[{"nameIdentifier":"635828","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"若月, 優"}],"nameIdentifiers":[{"nameIdentifier":"635829","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 義行"}],"nameIdentifiers":[{"nameIdentifier":"635830","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中野, 隆史"}],"nameIdentifiers":[{"nameIdentifier":"635831","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"若月 優","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"635832","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木 義行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"635833","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"子宮頸癌腔内照射時のハイリスクCTV線量の解析:D90の経時的変化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"子宮頸癌腔内照射時のハイリスクCTV線量の解析:D90の経時的変化"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-02-15"},"publish_date":"2012-02-15","publish_status":"0","recid":"64503","relation_version_is_last":true,"title":["子宮頸癌腔内照射時のハイリスクCTV線量の解析:D90の経時的変化"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:10:52.378053+00:00"}