{"created":"2023-05-15T14:46:58.512624+00:00","id":64444,"links":{},"metadata":{"_buckets":{"deposit":"943addf0-57e4-4439-9679-17eb21494e46"},"_deposit":{"created_by":1,"id":"64444","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"64444"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00064444","sets":["10:29"]},"author_link":["635364","635363"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2011-11-27","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"To compare the biological effectiveness of 6 cm SOBP carbon ion therapy beams between the GSI and NIRS. We tested the survival of human salivary gland tumor HSG cells and the crypt survival of C3H mice exposed to HIMAC and GSI carbon therapeutic beams with a 6 cm SOBP. The relative biological effectiveness of the SOBP beams was uniform, and no significant differences were noted when the depth-dose distribution was similar. However the depth-dose distribution between the HIMAC passive beam and the 4Gy RBE GIS spot scanning beam with LEM-I showed were different.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"2nd NIRS-ETOILE Joint Symposium on Carbon Ion Therapy","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Furusawa, Yoshiya"}],"nameIdentifiers":[{"nameIdentifier":"635363","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古澤 佳也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"635364","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"RBE of Therapeutic Hadron Beams at Clinical facilities and the Intercomparison","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"RBE of Therapeutic Hadron Beams at Clinical facilities and the Intercomparison"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-12-02"},"publish_date":"2011-12-02","publish_status":"0","recid":"64444","relation_version_is_last":true,"title":["RBE of Therapeutic Hadron Beams at Clinical facilities and the Intercomparison"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:11:33.182201+00:00"}