{"created":"2023-05-15T14:46:40.567007+00:00","id":64040,"links":{},"metadata":{"_buckets":{"deposit":"3d951eab-647e-48f8-bbc4-d8a21920da39"},"_deposit":{"created_by":1,"id":"64040","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"64040"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00064040","sets":["10:29"]},"author_link":["631794","631797","631799","631798","631795","631793","631796"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2009-09-10","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In order to understand responses of luminescence detectors as Thermo-Luminescence, Optically Stimulated Luminescence dosimeters for space radiation, an irradiation system has been prepared in the cyclotron in NIRS. The dosimeters can be exposed to 30 to 70 MeV protons. These middle energy particles have lower LET and they are suitable for researches around LET~1 keV/um where the response of the detectors have not been well known. The irradiation system and its dosimetry methodology in the cyclotron facility will be reported.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"14th WRMISS Workshop","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Uchihori, Yukio"}],"nameIdentifiers":[{"nameIdentifier":"631793","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yasuda, Nakahiro"}],"nameIdentifiers":[{"nameIdentifier":"631794","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kitamura, Hisashi"}],"nameIdentifiers":[{"nameIdentifier":"631795","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"631796","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内堀 幸夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"631797","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安田 仲宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"631798","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"631799","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Preparation of Proton Irradiation System for Intercomparison Experiments of Luminescence Detectors (Proton-ICCHIBAN-2)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Preparation of Proton Irradiation System for Intercomparison Experiments of Luminescence Detectors (Proton-ICCHIBAN-2)"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-10-01"},"publish_date":"2010-10-01","publish_status":"0","recid":"64040","relation_version_is_last":true,"title":["Preparation of Proton Irradiation System for Intercomparison Experiments of Luminescence Detectors (Proton-ICCHIBAN-2)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:16:06.940999+00:00"}