{"created":"2023-05-15T14:46:26.603628+00:00","id":63733,"links":{},"metadata":{"_buckets":{"deposit":"160a9ba2-22a9-4fb6-97ec-20444cd2c034"},"_deposit":{"created_by":1,"id":"63733","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"63733"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00063733","sets":["10:29"]},"author_link":["629050","629047","629046","629049","629048","629045"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2009-12-04","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"OSL個人線量計を用いた環境線量測定が盛んに行われた。しかし、この測定に用いた個人線量計は測定サービスを前提としたもので、読取装置は大型で移動させることが出来ず、線量計の配布回収による測定であった。OSLは高温を必要としないため読取システムの小型化が容易であり、使用する素子はフェ−ディングが小さく、物理的・化学的影響を受けにくいなど環境線量に適している。近年新しく開発されたInLightシステムはリーダが小型化され(最小でA4程度)、消費電力が小さく(PC用UPS等で長時間駆動可能)、線量計を設置した場所での線量読取が可能になる。この小型リーダの線量直線性を、137-Cs線源を用いて調べたところ、20μGyから10,000μGyまで良好な直線性を示した(変動計数:100μGy以下で10%超、200μGy以上で5%程度)。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本放射線安全管理学会 第8回学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小林, 育夫"}],"nameIdentifiers":[{"nameIdentifier":"629045","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢島, 千秋"}],"nameIdentifiers":[{"nameIdentifier":"629046","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"保田, 浩志"}],"nameIdentifiers":[{"nameIdentifier":"629047","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小林 育夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"629048","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢島 千秋","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"629049","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"保田 浩志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"629050","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"小型OSL線量読取装置による環境線量測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"小型OSL線量読取装置による環境線量測定"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-12-16"},"publish_date":"2009-12-16","publish_status":"0","recid":"63733","relation_version_is_last":true,"title":["小型OSL線量読取装置による環境線量測定"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:19:35.731919+00:00"}