{"created":"2023-05-15T14:46:17.373426+00:00","id":63226,"links":{},"metadata":{"_buckets":{"deposit":"e2873fd1-f3ef-417d-ac8d-c1d7d1d4dfeb"},"_deposit":{"created_by":1,"id":"63226","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"63226"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00063226","sets":["10:29"]},"author_link":["624396","624393","624399","624397","624400","624395","624394","624392","624401","624398"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2009-09-12","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【目的】子宮頸癌の高線量率腔内照射時にCT撮影を行い、リスク臓器について3次元の線量評価を行った。\n\\n【方法】当院で2008年7月から2009年3月に放射線治療を行った、子宮頸癌患者13例を対象とした。年齢の中央値は63歳(35-80歳)、臨床病期はIb1〜IIIb期であった。外部照射の総線量は50Gy(全骨盤に20-30Gy後、中央遮蔽)とし、腔内照射はA点に24Gy/4回を原則とした。腔内照射1回目と3回目にCTを撮影し、GEC-ESTROの勧告に従って膀胱・直腸に関して、3次元の線量−容量パラメータについて解析した。\n\\n【結果】直腸のD2ccはICRUの直腸線量と同等の値であったが(p=0.12)、膀胱のD2ccはICRUの膀胱線量より有意に高値であった(p<0.001)。\n\\n【結語】従来のICRUの線量評価点では、直腸線量は比較的適切に評価されていたが、膀胱尖量は過小評価されている可能性が示唆された。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第41回群馬放射線腫瘍研究会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大久保, 悠"}],"nameIdentifiers":[{"nameIdentifier":"624392","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加藤, 真吾"}],"nameIdentifiers":[{"nameIdentifier":"624393","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"清原, 浩樹"}],"nameIdentifiers":[{"nameIdentifier":"624394","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大野, 達也"}],"nameIdentifiers":[{"nameIdentifier":"624395","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田, 正"}],"nameIdentifiers":[{"nameIdentifier":"624396","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大久保 悠","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"624397","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加藤 眞吾","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"624398","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"清原 浩樹","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"624399","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大野 達也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"624400","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田 正","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"624401","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"子宮頸癌の高線量率腔内照射時CT撮影によるリスク臓器の2次元の線量評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"子宮頸癌の高線量率腔内照射時CT撮影によるリスク臓器の2次元の線量評価"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-09-14"},"publish_date":"2009-09-14","publish_status":"0","recid":"63226","relation_version_is_last":true,"title":["子宮頸癌の高線量率腔内照射時CT撮影によるリスク臓器の2次元の線量評価"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:21:46.071509+00:00"}