{"created":"2023-05-15T14:46:12.423963+00:00","id":63116,"links":{},"metadata":{"_buckets":{"deposit":"af978716-a5cb-466e-ace1-9bbbb0abeb0a"},"_deposit":{"created_by":1,"id":"63116","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"63116"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00063116","sets":["10:29"]},"author_link":["623486","623487","623484","623483","623482","623489","623480","623488","623481","623485"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2009-06-13","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"目的】子宮頚癌の高線量率腔内照射において、CTを用いた3次元の線量評価を行ったので報告する。\n\\n【対象および方法】当院で2008年7月〜2009年3月に放射線治療を行った子宮頚癌患者13例を対象とした。年齢の中央値は63歳(35-80歳)、臨床病期は?b1〜?b期であった。外部照射の総線量は50Gy(全骨盤に20-30Gy後、中央遮蔽)とし、腔内照射はA点に24Gy/4回を原則とした。腔内照射1回目と3回目にCTを撮影し、GEC-ESTROの勧告に従ってHR-CTV、IR-CTVおよび膀胱・直腸・S状結腸に関して、3次元の線量‐容積パラメータについて解析した。\n\\n【結果】直腸のD2ccはICRUの直腸線量と同等の値であったが(p=0.12)、膀胱のD2ccはICRUの膀胱線量より有意に高値であった(p<0.001)。外部照射と腔内照射を合計した総線量(EQD2)は、?-?期で腫瘍径4cm未満のものではHR-CTVのD90は中央値54.9Gy(48.8-68.0Gy)、IR-CTVのD90は中央値38.9Gy(35.4-42.0Gy)であった。一方、?-?期で腫瘍径4cm以上のものではHR-CTVのD90は中央値65.0Gy(57.7-77.4Gy)、IR-CTVのD90は中央値49.4Gy(45.6-52.9Gy)であった。初期治療効果(治療後6ヶ月以内の最大効果)は13例全例でCRであった。\n\\n【結語】従来のICRUの線量評価点では、直腸線量は比較的適切に評価されていたが、膀胱線量は過小評価されている可能性が示唆された。CTVへの投与線量は欧米で推奨されているものよりも少なかった。今後、局所制御および遅発性有害事象と3次元の線量‐容積パラメータとの相関について、長期的な検討が必要である。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本放射線腫瘍学会小線源治療部会第11回研究会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大久保, 悠"}],"nameIdentifiers":[{"nameIdentifier":"623480","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加藤, 真吾"}],"nameIdentifiers":[{"nameIdentifier":"623481","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"清原, 浩樹"}],"nameIdentifiers":[{"nameIdentifier":"623482","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大野, 達也"}],"nameIdentifiers":[{"nameIdentifier":"623483","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田, 正"}],"nameIdentifiers":[{"nameIdentifier":"623484","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大久保 悠","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"623485","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加藤 眞吾","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"623486","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"清原 浩樹","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"623487","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大野 達也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"623488","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田 正","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"623489","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"子宮頚癌の高線量率腔内照射におけるCTを用いた3次元の線量評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"子宮頚癌の高線量率腔内照射におけるCTを用いた3次元の線量評価"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-06-15"},"publish_date":"2009-06-15","publish_status":"0","recid":"63116","relation_version_is_last":true,"title":["子宮頚癌の高線量率腔内照射におけるCTを用いた3次元の線量評価"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:23:01.892989+00:00"}