{"created":"2023-05-15T14:46:00.641645+00:00","id":62853,"links":{},"metadata":{"_buckets":{"deposit":"ce0b773c-89d8-4b0b-8f6f-b861b6b71208"},"_deposit":{"created_by":1,"id":"62853","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"62853"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00062853","sets":["10:29"]},"author_link":["620854","620857","620858","620859","620856","620855"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-09-12","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":" 白金(Pt)の錯体は、抗ガン剤としてその研究と利用が進められ、マイクロPIXEシステムを用いたPtの細胞内分布が調べられている。PtのPIXEのスペクトル解析では、亜鉛(Zn)のZn KβとPt Lα線と重なることと、Znが生体必須元素あることから定量感度を求めることが急務とされている。これまで、粒径約25μmの球状イオン交換樹脂に、微量元素を吸着させた標準試料(SRM)を試作し、有効性を確かめてきた。本研究ではSRMに正確量のPtとZnを添加しマイクロビームによる特性X線強度と元素添加量とから分析感度を求めたので報告する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第25回PIXEシンポジウム","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩田, 吉弘"}],"nameIdentifiers":[{"nameIdentifier":"620854","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石井, 慶造"}],"nameIdentifiers":[{"nameIdentifier":"620855","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"横田, 渉"}],"nameIdentifiers":[{"nameIdentifier":"620856","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神谷, 富裕"}],"nameIdentifiers":[{"nameIdentifier":"620857","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤, 隆博"}],"nameIdentifiers":[{"nameIdentifier":"620858","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"及川, 将一"}],"nameIdentifiers":[{"nameIdentifier":"620859","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"イオン交換樹脂をもちいる標準物質によるマイクロビームシステムにおける亜鉛と白金に対する感度の測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"イオン交換樹脂をもちいる標準物質によるマイクロビームシステムにおける亜鉛と白金に対する感度の測定"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-11-18"},"publish_date":"2008-11-18","publish_status":"0","recid":"62853","relation_version_is_last":true,"title":["イオン交換樹脂をもちいる標準物質によるマイクロビームシステムにおける亜鉛と白金に対する感度の測定"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:26:00.186057+00:00"}