{"created":"2023-05-15T14:45:56.733101+00:00","id":62766,"links":{},"metadata":{"_buckets":{"deposit":"9faff8ff-b06f-4efa-8c2d-618baff2d5f5"},"_deposit":{"created_by":1,"id":"62766","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"62766"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00062766","sets":["10:29"]},"author_link":["619872","619871","619865","619875","619877","619866","619878","619874","619868","619879","619867","619876","619864","619870","619869","619873"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-04-15","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Possible induction of adaptive response by high LET irradiation of\naccelerated heavy ions is to be tested both in vivo in young adult mice and\nin utero in fetal mice of C57BL strain. Investigations are to verify 1) if\nthe known X-ray-induced adaptive response could reduce any heavy-ion-induced\ndetrimental effects such as death or malformation, 2) if the heavy ion\nirradiation at certain low dose could induce any adaptive response against\nthe detrimental effects induced by high dose of X-irradiations, and 3) if\nthe heavy-ion irradiation at certain low dose could induce any adaptive\nresponse against the detrimental effects induced by high dose of heavy ion\nirradiations. Three kinds of accelerated heavy ions are to be examined, 1)\ncarbon (290MeV/u) mono beams with a linear energy transfer (LET) value of\nabout 15 keV/mm, silicon (490MeV/u) mono beams with a LET value of about 55\nkeV/mm and ion (500MeV/u) mono beams with a LET value of about 200 keV/mm.\nAt the beginning of this work in the latter half of the fiscal year 2007, we\nsearched for the suitable challenging dose for either the fetal mice or the\nadult mice. In the first half of the fiscal year 2008, it will be the tasks\nto test if the priming low dose X-irradiations could induce any protective\neffect against the detrimental effects from the high LET heavy-ion\nchallenging irradiations. In the latter half of the fiscal year 2008, we\nwill try to check if the priming heavy-ion irradiations at certain low doses\ncould induce any protective effect against the detrimental effects from the\nhigh dose challenging X-irradiations. In the fiscal year 2009, both priming\nand challenging doses will be performed using heavy-ion irradiations, and we\nwould expect an answer to the raised question \"Does Radioadaptive Response\nAlso Apply to the Case of Heavy-ion Irradiations in Fetal and Adult Mice?\"\nand find some evidential clue to the mechanisms underlying these phenomena.\nThe work on searching for the suitable challenging dose for the in utero\nexperiment is finished while the work is undergoing for the in vivo\nexperiment. Here the obtained data so far are presented in this annual\nresearch report meeting.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"平成19年度放射線医学総合研究所重粒子線がん治療装置等共同利用研究発表会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"王, 冰"}],"nameIdentifiers":[{"nameIdentifier":"619864","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田中, 薫"}],"nameIdentifiers":[{"nameIdentifier":"619865","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Guillaume, Vares"}],"nameIdentifiers":[{"nameIdentifier":"619866","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尚, 奕"}],"nameIdentifiers":[{"nameIdentifier":"619867","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"二宮, 康晴"}],"nameIdentifiers":[{"nameIdentifier":"619868","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤田, 和子"}],"nameIdentifiers":[{"nameIdentifier":"619869","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"笠井, 清美"}],"nameIdentifiers":[{"nameIdentifier":"619870","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"根井, 充"}],"nameIdentifiers":[{"nameIdentifier":"619871","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"王 冰","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619872","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田中 薫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619873","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Guillaume Vares","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619874","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尚 奕","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619875","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"二宮 康晴","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619876","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤田 和子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619877","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"笠井 清美","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619878","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"根井 充","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619879","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"胎児・成体マウスにおける放射線誘発適応応答は重粒子線にも当て嵌まるか","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"胎児・成体マウスにおける放射線誘発適応応答は重粒子線にも当て嵌まるか"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-10-08"},"publish_date":"2008-10-08","publish_status":"0","recid":"62766","relation_version_is_last":true,"title":["胎児・成体マウスにおける放射線誘発適応応答は重粒子線にも当て嵌まるか"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:27:01.910498+00:00"}