{"created":"2023-05-15T14:45:55.158332+00:00","id":62731,"links":{},"metadata":{"_buckets":{"deposit":"8395dbe3-feff-48b1-9b1e-dbf192ec14b6"},"_deposit":{"created_by":1,"id":"62731","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"62731"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00062731","sets":["10:29"]},"author_link":["619606","619609","619605","619608","619604","619607","619603"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-09-12","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We calculated the secondary neutrons produced in the phantom and the beam line devices during passive carbon-ion radiotherapy with the PHITS code and verified the calculation experimentally. The calculations with the PHITS code agree with the Bonner sphere system measurements within 35 % and the calculated ambient dose equivalents agree well with the measurements within 7 %. We confirmed that the PHITS code has potential ability to evaluate the neutron exposure in carbon-ion radiotherapy.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"The 5th KOREA-JAPAN Joint Meeting on Medical Physics","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yonai, Shunsuke"}],"nameIdentifiers":[{"nameIdentifier":"619603","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsufuji, Naruhiro"}],"nameIdentifiers":[{"nameIdentifier":"619604","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"619605","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"619606","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"米内 俊祐","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619607","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松藤 成弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619608","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619609","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Monte Carlo calculation of secondary neutrons in passive carbon-ion radiotherapy and its experimental verification","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Monte Carlo calculation of secondary neutrons in passive carbon-ion radiotherapy and its experimental verification"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-09-22"},"publish_date":"2008-09-22","publish_status":"0","recid":"62731","relation_version_is_last":true,"title":["Monte Carlo calculation of secondary neutrons in passive carbon-ion radiotherapy and its experimental verification"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:27:25.836902+00:00"}