{"created":"2023-05-15T14:45:54.526482+00:00","id":62717,"links":{},"metadata":{"_buckets":{"deposit":"5c0ec5c7-790c-4560-87e7-998146bd147c"},"_deposit":{"created_by":1,"id":"62717","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"62717"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00062717","sets":["10:29"]},"author_link":["619531","619529","619530","619524","619523","619527","619525","619528","619526"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-09-12","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Nation-wide proton dosimetry intercomparison was carried out involving new facilities in April 2008. The absorbed dose to water was estimated independently by participants with both ND,w and NX calibration factors. The results showed good agreement within standard deviation less than 0.4% for both cases. The uncertainty for ND,w method was smaller than that of NX.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"The 5th Korea - Japan Joint Meeting on Medical Physics(第96回日本医学物理学会学術大会)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Fukumura, Akifumi"}],"nameIdentifiers":[{"nameIdentifier":"619523","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizuno, Hideyuki"}],"nameIdentifiers":[{"nameIdentifier":"619524","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nagano, Ai"}],"nameIdentifiers":[{"nameIdentifier":"619525","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"619526","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"619527","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福村 明史","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619528","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水野 秀之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619529","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永野 あい","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619530","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"619531","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Proton Beam Dosimetry Intercomparison Based on Standards of Absorbed Dose to Water","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Proton Beam Dosimetry Intercomparison Based on Standards of Absorbed Dose to Water"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-09-16"},"publish_date":"2008-09-16","publish_status":"0","recid":"62717","relation_version_is_last":true,"title":["Proton Beam Dosimetry Intercomparison Based on Standards of Absorbed Dose to Water"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:27:35.152326+00:00"}