{"created":"2023-05-15T14:45:44.302761+00:00","id":62488,"links":{},"metadata":{"_buckets":{"deposit":"64203133-b7c9-4432-ac68-21028b412235"},"_deposit":{"created_by":1,"id":"62488","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"62488"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00062488","sets":["10:29"]},"author_link":["617371","617372"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-03-24","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Abstract: A new treatment facility project that will be an extension of the existing HIMAC complex, has been initiated for the further development of carbon-ion therapy. This new treatment facility will be equipped with a three-dimensional irradiation system with pencil beam scanning. For the high-accuracy treatment of moving tumors , the most important criterion for the design study is how to realize this goal by scanning irradiation. For this purpose, we have studied a combination of the rescanning technique and the gated irradiation method. In order to avoid hot and/or cold spots even by a relatively larger number of rescans within an acceptable irradiation time, we studied a fast scanning system. Further, this concept was experimentally demonstrated at the HIMAC. The design and the related study of the scanning system for the new HIMAC treatment facility is presented below.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"NIRS MD Anderson Symposium on Clinical Issues for Particle Therapy","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Furukawa, Takuji"}],"nameIdentifiers":[{"nameIdentifier":"617371","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 卓司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"617372","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"NIRS Scanning","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"NIRS Scanning"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-03-26"},"publish_date":"2008-03-26","publish_status":"0","recid":"62488","relation_version_is_last":true,"title":["NIRS Scanning"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:30:13.116950+00:00"}