{"created":"2023-05-15T14:45:31.798432+00:00","id":62212,"links":{},"metadata":{"_buckets":{"deposit":"8e1e06cd-8b03-4d61-b6ed-f3ec2303ef1f"},"_deposit":{"created_by":1,"id":"62212","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"62212"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00062212","sets":["10:29"]},"author_link":["615051","615053","615052","615059","615058","615054","615057","615056","615060","615055","615062","615061"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2007-09-12","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"大気中に置かれた試料をそのままの状態で分析できる気中取り出しによるPIXE分析法は、液状の試料をそのままの状態で測定できる等の利点があることから、放医研では、液滴PIXE分析装置(droplet-PIXE)としてユーザの利用に供している。気中取り出しPIXEにおいては、元素濃度の定量に必要となる陽子線の照射量をターゲットの電流積算量として正確に把握することは、気中であるが故に難しいとされている1)。そこで我々は、外部標準法による液体試料の定量測定の一つ方法として、ビーム取り出し口に置く、極く小さなイオンチャンバーを設計・試作し照射量を把握する方法としての有用性を確認し、droplet-PIXEとして報告した2)。今回、検出感度を上げて欲しい等のユーザの要求に応えるため、droplet-PIXEの改造の検討を開始した。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第24回PIXEシンポジウム","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"615051","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯, 浩之"}],"nameIdentifiers":[{"nameIdentifier":"615052","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西, 輝昭"}],"nameIdentifiers":[{"nameIdentifier":"615053","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋, 徳啓"}],"nameIdentifiers":[{"nameIdentifier":"615054","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野, 毅"}],"nameIdentifiers":[{"nameIdentifier":"615055","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"615056","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"615057","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯 浩之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"615058","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西 輝昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"615059","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋 徳啓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"615060","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野 毅","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"615061","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"615062","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"液滴PIXE分析装置Droplet PIXE?の開発 その1","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"液滴PIXE分析装置Droplet PIXE?の開発 その1"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-09-13"},"publish_date":"2007-09-13","publish_status":"0","recid":"62212","relation_version_is_last":true,"title":["液滴PIXE分析装置Droplet PIXE?の開発 その1"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:33:22.033563+00:00"}