{"created":"2023-05-15T14:45:26.049415+00:00","id":62083,"links":{},"metadata":{"_buckets":{"deposit":"a5a7ffec-666c-4286-b989-0561333be8bc"},"_deposit":{"created_by":1,"id":"62083","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"62083"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00062083","sets":["10:29"]},"author_link":["613956","613957","613954","613955","613953"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2007-04-27","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"放射性リガンドの体内分布を、陽電子断層装置(Positron Emission Tomography; PET)で撮影す\nることで、神経受容体濃度の定量画像撮影が可能となる。しかし、撮影には、血中放射能濃度\n曲線(pTAC)測定のための連続動脈採血を伴うことから、特に痴呆患者や小児症例への適用、あ\nるいはラット等の小動物撮影において問題となる。そこで本研究では、神経受容体イメージン\nグで多用されるLogan plot[1]に基づき、かつ、対象組織内ではpTAC が共通であることを考慮す\nることで、pTAC を推定するアルゴリズム平面交差法の[2]、耐雑音性向上手法を提案し、実際\nの臨床データへの適用を通し、その妥当性を検討する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第46回日本生体医工学会大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"木村, 裕一"}],"nameIdentifiers":[{"nameIdentifier":"613953","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長縄, 美香"}],"nameIdentifiers":[{"nameIdentifier":"613954","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"その他"}],"nameIdentifiers":[{"nameIdentifier":"613955","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"木村 裕一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"613956","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長縄 美香","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"613957","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"放射性リガンドの体内分布を、陽電子断層装","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"放射性リガンドの体内分布を、陽電子断層装"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-05-01"},"publish_date":"2007-05-01","publish_status":"0","recid":"62083","relation_version_is_last":true,"title":["放射性リガンドの体内分布を、陽電子断層装"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:34:53.709520+00:00"}