{"created":"2023-05-15T14:45:13.985222+00:00","id":61812,"links":{},"metadata":{"_buckets":{"deposit":"536a5155-9aa1-4104-8b49-f775e542e6eb"},"_deposit":{"created_by":1,"id":"61812","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"61812"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00061812","sets":["10:29"]},"author_link":["611840","611841"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2006-09-21","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Abstract. Four ECR ion sources have been operated in National Institute of Radiological Sciences (NIRS). Two ECR ion sources supply various ion species for the Heavy Ion Medical Accelerator in Chiba (HIMAC). The 10 GHz NIRS-ECR ion source mainly produces C2+ ions for the heavy-ion therapy. Ions of Si, Ar, Fe, Kr and Xe are usually produced by the 18 GHz NIRS-HEC ion source for physical and biological experiments. The other two compact ECR ion sources with all permanent magnet configuration have been developed for the new generation carbon therapy facility. One of these, the Kei-source, is a prototype which has been installed to the NIRS-930 cyclotron for axial injection. The other source, Kei2-source, is a demonstration source and utilized for the new generation Linac. In addition, both Kei sources have been used to study fundamental properties.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第17回ECRイオン源とその応用に関する国際ワークショップ","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Muramatsu, Masayuki"}],"nameIdentifiers":[{"nameIdentifier":"611840","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村松 正幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"611841","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Present status of NIRS ECR ion sources","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Present status of NIRS ECR ion sources"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-09-29"},"publish_date":"2006-09-29","publish_status":"0","recid":"61812","relation_version_is_last":true,"title":["Present status of NIRS ECR ion sources"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:38:01.429885+00:00"}