{"created":"2023-05-15T14:44:54.278623+00:00","id":61373,"links":{},"metadata":{"_buckets":{"deposit":"9bf1487f-15ad-40f9-b067-68a439f8bb8e"},"_deposit":{"created_by":1,"id":"61373","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"61373"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00061373","sets":["10:29"]},"author_link":["607375","607373","607374","607372"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2002-09-20","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In the present study, we performed tracer experiments to compare the elution behaviors of Tc and Re through a TEVA resin column to measure 99Tc and Re in environmental samples. From a practical viewpoint, enriched 185Re is a good yield monitor for 99Tc and Re in water samples. The TEVA resin showed a high selectivity for Tc and Re in ca. a 0.1M HNO3 solution. When an appropriate combination of nitric acid solutions, that is, 1M and 8M, was used for washing and stripping, respectively, the elution behaviors of Tc and Re were the same. Both elements could be concentrated in 5 mL of 8M HNO3. Mo has an isotopic abundance of 24.13% at mass 98, which might interfere with the measurement of 99Tc by ICP-MS as 98MoH+, however, the resin did not sorb other matrix elements including Mo under the cited condition for nitric acid solutions. Thus, the resin was applicable to determination of Tc and Re concentrations in natural water samples by ICP-MS using enriched 185Re as a yield tracer.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"9th International Symposium on Environmental Radiochemical Analysis","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Uchida, Shigeo"}],"nameIdentifiers":[{"nameIdentifier":"607372","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tagami, Keiko"}],"nameIdentifiers":[{"nameIdentifier":"607373","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"607374","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上 恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"607375","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Elution behavior of technetium and rhenium through a Tc-selective chromatographic resin column","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Elution behavior of technetium and rhenium through a Tc-selective chromatographic resin column"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-06-05"},"publish_date":"2006-06-05","publish_status":"0","recid":"61373","relation_version_is_last":true,"title":["Elution behavior of technetium and rhenium through a Tc-selective chromatographic resin column"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:43:09.987723+00:00"}