{"created":"2023-05-15T14:44:52.214409+00:00","id":61330,"links":{},"metadata":{"_buckets":{"deposit":"74da8c29-3b13-4a89-a2d3-9bd953690ad9"},"_deposit":{"created_by":1,"id":"61330","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"61330"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00061330","sets":["10:29"]},"author_link":["606960","606958","606957","606955","606954","606959","606953","606956"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2006-03-09","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"MRI(Magnetic Resonance Imaging:磁気共鳴画像法)は、強い静磁界中におかれた生体にパルス状電磁波を照射することによって、その生体組織中に励起された水素原子核スピンが緩和することに伴って誘導される電磁波を受信し、生体内部を画像化する方法である。本システムは、様々な要素によって成り立ち、その一つにRF(Radio Frequency)コイルがある。これは、”生体にパルス状電磁波を照射しNMR(Nuclear Magnetic Resonance:核磁気共鳴)信号を生じさせる”、”生体が発生するNMR信号を受信する”という2つの役割をもつアンテナとしてはたらく。近年、妊娠女性がMRIを利用した際における、RFコイルから発せられる電磁波によるSAR(Specific Absorption Rate:比吸収率)評価の必要性が論議されている。そこで本検討では、FDTD(Finite Defferecnce Time Domain:時間領域差分)法により、コウ精細な女性数値モデルを用いて、妊娠女性腹部のSARに関する基礎検討を行った。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"環境電磁工学研究会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"天野, 智正"}],"nameIdentifiers":[{"nameIdentifier":"606953","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"齊藤, 一幸"}],"nameIdentifiers":[{"nameIdentifier":"606954","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤, 公一"}],"nameIdentifiers":[{"nameIdentifier":"606955","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平, 博夫"}],"nameIdentifiers":[{"nameIdentifier":"606956","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"その他"}],"nameIdentifiers":[{"nameIdentifier":"606957","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"齊藤 一幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"606958","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤 公一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"606959","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平 博夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"606960","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"MRI用バードケージコイル使用時の女性腹部のSAR評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"MRI用バードケージコイル使用時の女性腹部のSAR評価"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-04-06"},"publish_date":"2006-04-06","publish_status":"0","recid":"61330","relation_version_is_last":true,"title":["MRI用バードケージコイル使用時の女性腹部のSAR評価"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:43:38.482725+00:00"}