{"created":"2023-05-15T14:44:46.512735+00:00","id":61202,"links":{},"metadata":{"_buckets":{"deposit":"ef66cd51-3273-4a81-8468-232087419733"},"_deposit":{"created_by":1,"id":"61202","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"61202"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00061202","sets":["10:29"]},"author_link":["606082","606080","606083","606081"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2003-07-25","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A separation method using TEVA Spec resin (Eichrom Industries. Inc.) was studied for a simple and rapid measurement of uranium isotopic mass ratio in environmental soil samples by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS). The resin, charged in a minicolumn, retained U from a 20-mL sample solution adjusted to 6M HCl. After washing the column with 6M HCl, U was eluted with 20 mL of 1 M HCl. Through this separation process, U in a standard solution was purified from major and minor elements including Fe. Subsequently, the method was also applied to actual soil sample solutions, but U could not be separated from Fe. This was possibly attributed to Fe contents in the samples being higher than in that in the standard solution, and Fe would affect U sorption onto the resin. However, the separation method could separate U from major matrix elements in soil and the isotopic mass ratios of 235U/238U and 234U/238U could be measured by Q-ICP-MS using a 0.1 g sample of dried soil.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"The second International Symposium on Radiation Safety and Detection Technology","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tagami, Keiko"}],"nameIdentifiers":[{"nameIdentifier":"606080","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchida, Shigeo"}],"nameIdentifiers":[{"nameIdentifier":"606081","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上 恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"606082","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"606083","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Development of a separation method for uranium isotopic mass ratio measurement in environmental samples by ICP-MS","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a separation method for uranium isotopic mass ratio measurement in environmental samples by ICP-MS"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-12-05"},"publish_date":"2005-12-05","publish_status":"0","recid":"61202","relation_version_is_last":true,"title":["Development of a separation method for uranium isotopic mass ratio measurement in environmental samples by ICP-MS"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:45:05.952679+00:00"}