{"created":"2023-05-15T14:44:42.120974+00:00","id":61105,"links":{},"metadata":{"_buckets":{"deposit":"3a1dd37e-16ed-4b9a-8519-839260a31b9f"},"_deposit":{"created_by":1,"id":"61105","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"61105"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00061105","sets":["10:29"]},"author_link":["605317","605324","605320","605322","605325","605316","605315","605319","605323","605321","605318","605314"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2005-10-02","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【目的】 微生物汚染の有無を確認するために、モニター動物を検疫動物近くに配置し、ケージ交換時に検疫動物の汚物の一部をモニター動物の床敷の中に入れたり、飼育装置の排気をモニター動物と接触させることなどを行い、微生物汚染の検出感度を高める工夫がなされている。今回飼育ケージの蓋を改良して2区画に分割し、片側に微生物汚染動物を、もう片方に健常動物を配置して、汚染の広がりかたをみることで、改良した飼育ケージの有用性について検討した。\n【材料と方法】微生物汚染源としてCilia-associated respiratory (CAR) bacillusを用いた。CAR bacillusはBALB/c-nu/+ マウスに対して高感受性であることから、SMR株2×100000個/20μl/匹を6週齢雌マウス16匹に経鼻接種した。感染マウス2匹に対し、健常マウス3匹の割合で2分割ケージにて飼育し、感染7、14、21、28、35、42、49、56日後に感染マウスおよび同居させたマウスの鼻腔、気管、肺からCAR bacillusが検出されるかについてPCR診断を行った。なお鼻腔のスワブ採取には滅菌したケント紙を用いた。また同時に呼吸器系の組織検査、CAR bacillusの血清抗体価をIFA法にて調べた。\n【結果と総括】鼻腔に損傷を与えることなくスワブを採取する方法を検討し、その材料からCAR bacillus のPCR陽性結果が得られており、動物を屠殺することなく微生物検査が可能となった。菌接種マウスでは、7日目のPCR検査で陽性、14日目から病理組織検査で菌体を確認、抗体価の上昇も認められました。同居マウスでは、28日目からPCR検査陽性、病理組織検査でも28日目に菌体を確認した。抗体価の上昇は、PCR陽性から2週間遅れ、42日目からみられた。\n検討したケージは、呼吸器系を介した接触感染の検出が可能であり、検疫用ケージとして有用であると考える。また生検材料しか得られない導入動物等に対して、口腔および鼻腔スワブのPCR検査が、呼吸器感染症の確認として有用であると考える。\n ケント紙による鼻腔スワブの採取は、組織損傷が少ないので、導入動物ないしモニター動物から複数回の採材が可能であると思われる。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第140回日本獣医学会学術集会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小久保, 年章"}],"nameIdentifiers":[{"nameIdentifier":"605314","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池田, 学"}],"nameIdentifiers":[{"nameIdentifier":"605315","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白石, 美代子"}],"nameIdentifiers":[{"nameIdentifier":"605316","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"入谷, 理一郎"}],"nameIdentifiers":[{"nameIdentifier":"605317","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"渡邊, 香里"}],"nameIdentifiers":[{"nameIdentifier":"605318","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松下, 悟"}],"nameIdentifiers":[{"nameIdentifier":"605319","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小久保 年章","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"605320","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池田 学","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"605321","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白石 美代子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"605322","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"入谷 理一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"605323","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"舘野 香里","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"605324","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松下 悟","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"605325","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"2分割用ケージ蓋を用いた検疫効果の有用性検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"2分割用ケージ蓋を用いた検疫効果の有用性検討"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-10-06"},"publish_date":"2005-10-06","publish_status":"0","recid":"61105","relation_version_is_last":true,"title":["2分割用ケージ蓋を用いた検疫効果の有用性検討"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:46:10.837545+00:00"}